Lithonia Lighting SB 232 120 GESB

Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

Model: SB 232 120 GESB

1. પરિચય

This manual provides instructions for the safe installation, operation, and maintenance of the Lithonia Lighting SB 232 120 GESB Wraparound 2-head Narrow Body T8 Fluorescent Ceiling Fixture. This fixture is designed for general illumination in various indoor settings such as storage rooms, offices, or retail applications. Key features include a hinged design for easy cleaning, an instant-on electronic ballast to eliminate flickering and humming, and a prismatic diffuser for controlled light distribution.

Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

Image 1.1: Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture.

2. સલામતી માહિતી

ચેતવણી: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. Improper wiring can result in electric shock or fire.

  • Always turn off the main power supply before attempting any installation, maintenance, or bulb replacement.
  • જો તમે ઇલેક્ટ્રિકલ વાયરિંગથી પરિચિત ન હોવ તો લાયક ઇલેક્ટ્રિશિયનનો સંપર્ક કરો.
  • ખાતરી કરો કે બધા વાયરિંગ કનેક્શન સુરક્ષિત છે અને સ્થાનિક ઇલેક્ટ્રિકલ કોડ્સનું પાલન કરે છે.
  • ઇન્સ્ટોલેશન દરમિયાન યોગ્ય વ્યક્તિગત રક્ષણાત્મક સાધનો, જેમ કે સલામતી ચશ્મા અને મોજા પહેરો.
  • Handle the fixture carefully to avoid sharp edges.
  • આ ફિક્સ્ચર માત્ર ઇન્ડોર ઉપયોગ માટે રચાયેલ છે.

3. પેકેજ સામગ્રી

ઇન્સ્ટોલેશન શરૂ કરતા પહેલા ખાતરી કરો કે બધા ઘટકો હાજર છે:

  • 1 x Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

નોંધ: Fluorescent T8 bulbs, mounting hardware (screws/anchors), and wire nuts are NOT included and must be purchased separately.

4. સ્પષ્ટીકરણો

બ્રાન્ડલિથોનિયા લાઇટિંગ
મોડલ નંબરSB 232 120 GESB
ભાગtage120 વોલ્ટ
વાટtage32 Watts (per lamp)
એલ ની સંખ્યાamps2 (T8 Fluorescent)
બેલાસ્ટ પ્રકારResidential Electronic Ballast
સામગ્રીSteel (housing), Acrylic (diffuser)
સમાપ્ત કરોWhite Enamel
પરિમાણો (L x W x H)48 ઇંચ x 8.5 ઇંચ X 2 ઇંચ
માઉન્ટિંગ પ્રકારSurface Mount, Stem Mount
પ્રમાણપત્રોcUL લિસ્ટેડ
Dimensions of Lithonia Lighting SB 232 120 GESB fixture: 48 inches long, 8.5 inches wide, 2 inches high

Image 4.1: Product dimensions of the SB 232 120 GESB fixture.

5. સ્થાપન

Follow these steps for proper installation. Ensure power is disconnected before proceeding.

5.1. તૈયારી

  • સર્કિટ બ્રેકર અથવા ફ્યુઝ બોક્સ પર પાવર બંધ કરો.
  • Gather necessary tools: screwdrivers, wire strippers, drill, appropriate mounting hardware (screws/anchors), and wire nuts (all not included).
  • Unpack the fixture and inspect for any damage.

5.2. ફિક્સ્ચર માઉન્ટ કરવું

  • Determine the desired mounting location on the ceiling for surface mounting or identify points for stem mounting.
  • For surface mounting, align the fixture and mark the drilling points for securing it to the ceiling joists or using appropriate anchors.
  • For stem mounting, the fixture requires a minimum of two single stem hangers (not included).
  • Secure the fixture firmly to the mounting surface using the appropriate hardware. Note that the wire entry tabs are located on the top of the fixture, requiring access from above for wiring.
Diagram showing surface or stem mounting options for the fixture, indicating two lamps and broad light distribution

Image 5.1: Mounting options and features of the fixture.

5.3. વાયરિંગ

  • Route the electrical supply wires into the fixture's wiring compartment.
  • Connect the supply wires to the fixture's pre-wired connections using wire nuts (not included). Ensure proper polarity (live to live, neutral to neutral, ground to ground).
  • The fixture may feature push-lok connectors for simplified wiring. Ensure wires are fully inserted and secure.
  • Carefully tuck all wires into the wiring compartment and secure any covers.

૪. બલ્બ ઇન્સ્ટોલેશન

  • Install two T8 fluorescent bulbs (not included) into the lamp holders by aligning the pins with the sockets and twisting gently until secure.

5.5. Diffuser Installation

  • Attach the prismatic acrylic diffuser to the fixture. The hinged design allows it to snap into place or be secured with latches.

6. ઓપરેશન

Once installation is complete and verified, restore power to the circuit. The fixture will illuminate immediately upon activation of the wall switch, thanks to its instant-on electronic ballast, which prevents flickering and humming.

7. જાળવણી

Regular maintenance ensures optimal performance and longevity of your fixture.

7.1. સફાઈ

  • સફાઈ કરતા પહેલા હંમેશા પાવર ડિસ્કનેક્ટ કરો.
  • The hinged design of the diffuser allows for easy access. Open the diffuser carefully.
  • Clean the diffuser and the exterior surfaces of the fixture with a soft, damp કાપડ
  • Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or acrylic diffuser.
  • પાવર પુનઃસ્થાપિત કરતા પહેલા ખાતરી કરો કે બધા ભાગો સુકા છે.

7.2. બલ્બ રિપ્લેસમેન્ટ

  • Always disconnect power before replacing bulbs.
  • Open the hinged diffuser to access the bulbs.
  • Carefully remove the old T8 fluorescent bulbs by twisting them to disengage from the sockets.
  • Insert new T8 fluorescent bulbs, ensuring the pins are properly aligned with the sockets, and twist gently until secure.
  • Close the diffuser securely.
  • ફિક્સ્ચરમાં પાવર પુનઃસ્થાપિત કરો.

8. મુશ્કેલીનિવારણ

If you encounter issues with your fixture, refer to the following troubleshooting guide:

સમસ્યાસંભવિત કારણઉકેલ
લાઈટ ચાલુ થતી નથીવીજ પુરવઠો નથી
ખામીયુક્ત બલ્બ
છૂટક વાયરિંગ કનેક્શન
સર્કિટ બ્રેકર/ફ્યુઝ તપાસો
Replace bulbs with known good ones
Inspect and secure all wiring connections (with power off)
Light flickers or humsBulbs not fully seated
Faulty ballast (rare for instant-on)
છૂટક વાયરિંગ
Ensure bulbs are firmly in sockets
If flickering/humming persists, consult an electrician to check ballast
Verify wiring connections are secure (with power off)
અસમાન પ્રકાશ વિતરણDiffuser improperly seated
ખોટો બલ્બ પ્રકાર/વોટtage
Ensure diffuser is correctly installed
Verify T8 bulbs of correct wattage are used

9. વોરંટી અને સપોર્ટ

This Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture is backed by a ૧ વર્ષની મર્યાદિત ઉત્પાદકની વોરંટી ખરીદીની તારીખથી.

This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, accident, misuse, abuse, or unauthorized modifications.

For technical support, warranty claims, or further assistance, please contact Lithonia Lighting customer service. Refer to the official Lithonia Lighting webવર્તમાન સંપર્ક માહિતી માટે સાઇટ.

© 2024 Lithonia Lighting. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.