UMLIFE W3001
UMLIFE XH-W3001 Digital LED Temperature Controller Module User Manual
Model: XH-W3001
Brand: UMLIFE
ઉત્પાદન ઓવરview
The UMLIFE XH-W3001 Digital LED Temperature Controller Module is a versatile thermostat switch designed for precise temperature control in various applications. It features a clear digital display and a waterproof NTC10K probe, making it suitable for both heating and cooling modes. Its robust ABS flame retardant housing ensures safety and durability.

Figure 1: UMLIFE XH-W3001 Digital LED Temperature Controller Module with probe and wiring.
મુખ્ય લક્ષણો
- એલઇડી સૂચક પ્રકાશ: Displays the current output status for easy monitoring.
- Digital Display Tube: Shows measuring temperature with high accuracy.
- બે કાર્ય સ્થિતિઓ: Supports both heating (start temperature < stop temperature) and cooling (start temperature > stop temperature) operations.
- વિશાળ તાપમાન શ્રેણી: Operates from -50℃ to 110℃ with a control precision of 0.1℃.
- ટકાઉ આવાસ: Constructed with ABS flame retardant material for high safety, aging resistance, and durability.
- વોટરપ્રૂફ પ્રોબ: Equipped with a 1-meter NTC10K stainless steel probe that is waterproof and rust-resistant.
સેટઅપ અને વાયરિંગ
Proper wiring is crucial for the safe and correct operation of the XH-W3001 module. Ensure all connections are secure before applying power.

Figure 2: Wiring diagram for the 12V XH-W3001 model. Connect the 12V input (red/black wires) to your power source. The output (yellow/black wires) connects to your load (e.g., a light bulb or fan). The sensor probe connects to the designated port.
વાયરિંગ સૂચનાઓ:
- પાવર ઇનપુટ: Connect the red wire to the positive (+) terminal of your 12V DC power supply and the black wire to the negative (-) terminal.
- લોડ આઉટપુટ: Connect the yellow wire to the positive (+) terminal of your heating or cooling device (load) and the black wire to the negative (-) terminal of the load. Ensure the load's voltage matches the controller's input voltage (12V).
- તાપમાન તપાસ: Insert the NTC10K waterproof probe into the designated two-pin connector on the module.

Figure 3: Labeled components of the XH-W3001 module, showing the temperature LED display, indicator light, up button, down button, and model number.
ઓપરેટિંગ સૂચનાઓ
The XH-W3001 has two main parameters to set: the start temperature and the stop temperature.
Setting Start Temperature:
- દબાવો અને પકડી રાખો અપ બટન (left button) for approximately 3 seconds. The display will start flashing, indicating it's in setting mode.
- નો ઉપયોગ કરો Up અને ડાઉન બટનો to adjust the desired start temperature.
- દબાવો અપ બટન again or wait for 3 seconds for the setting to be saved automatically.
Setting Stop Temperature:
- દબાવો અને પકડી રાખો ડાઉન બટન (right button) for approximately 3 seconds. The display will start flashing.
- નો ઉપયોગ કરો Up અને ડાઉન બટનો to adjust the desired stop temperature.
- દબાવો ડાઉન બટન again or wait for 3 seconds for the setting to be saved automatically.
ઓપરેટિંગ મોડ્સ:
- હીટિંગ મોડ: If the Start Temperature is set નીચું than the Stop Temperature, the module will operate in heating mode. The output will turn ON when the temperature drops below the Start Temperature and turn OFF when it reaches the Stop Temperature.
- કૂલિંગ મોડ: If the Start Temperature is set ઉચ્ચ than the Stop Temperature, the module will operate in cooling mode. The output will turn ON when the temperature rises above the Start Temperature and turn OFF when it drops to the Stop Temperature.
Note: The display shows temperature in Celsius only. There is no option to change to Fahrenheit.
જાળવણી
The XH-W3001 module is designed for low maintenance. Regular checks can ensure its longevity and accurate performance.
- સફાઈ: Keep the module and probe clean. Use a soft, dry cloth to wipe the display and housing. For the probe, ensure it is free from debris that might affect temperature readings.
- જોડાણો: Periodically check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or damage.
- ચકાસણી સ્થિતિ: Inspect the temperature probe for any signs of damage to the cable or the sensor tip. Replace if damaged to maintain accuracy.
- પર્યાવરણ: Ensure the module is installed in an environment within its specified operating temperature and humidity ranges to prevent premature failure.
મુશ્કેલીનિવારણ
If you encounter issues with your XH-W3001 module, refer to the following common problems and solutions:
| સમસ્યા | સંભવિત કારણ | ઉકેલ |
|---|---|---|
| Display not lighting up. | No power, incorrect wiring, or faulty unit. | Check power supply connections. Ensure correct polarity. Verify power source is active. |
| તાપમાન વાંચન ખોટું છે. | Damaged probe, probe not properly connected, or environmental interference. | Ensure probe is securely connected. Inspect probe for physical damage. Test with another known accurate thermometer if possible. |
| Output not switching ON/OFF as expected. | Incorrect start/stop temperature settings, load not connected, or faulty relay. | Review and re-set start/stop temperatures. Verify load connections. Ensure the load's power requirements are within the module's specifications (10A 120W for 12V model). |
| Display shows "LLL" or "HHH". | "LLL" indicates open circuit or probe not connected. "HHH" indicates short circuit or temperature exceeding range. | Check probe connection. Replace probe if damaged. Ensure temperature is within -50℃ to 110℃ range. |
વિશિષ્ટતાઓ
| લક્ષણ | સ્પષ્ટીકરણ |
|---|---|
| મોડલ નંબર | XH-W3001 |
| ભાગtage | 12 Volts (for this specific model) |
| આઉટપુટ વર્તમાન | મહત્તમ 10A |
| આઉટપુટ પાવર | Max 120W (for 12V model) |
| તાપમાન નિયંત્રણ શ્રેણી | -50 ℃ થી 110 ℃ |
| તાપમાન માપન ચોકસાઈ | ±0.2℃ |
| તાપમાન નિયંત્રણ ચોકસાઈ | ±0.1℃ |
| ચકાસણી પ્રકાર | NTC10K (Waterproof) |
| ડિસ્પ્લે પ્રકાર | એલઇડી ડિજિટલ ડિસ્પ્લે |
| હાઉસિંગ સામગ્રી | ABS ફ્લેમ રિટાડન્ટ |
| ઉત્પાદન પરિમાણો | 3.3 x 1.8 x 1.1 ઇંચ |
| વસ્તુનું વજન | ૬.૭ ઔંસ (૧૮૮.૮ ગ્રામ) |
વોરંટી અને આધાર
For warranty information or technical support regarding your UMLIFE XH-W3001 Digital LED Temperature Controller Module, please refer to the product packaging or contact UMLIFE customer service directly. Contact details are typically provided with your purchase or can be found on the manufacturer's official webસાઇટ
Ask a question about this manual