એપેરા ઇન્સ્ટ્રુમેન્ટ્સ AI532
Apera Instruments EC820 Benchtop Conductivity Meter Kit
વપરાશકર્તા માર્ગદર્શિકા
૧. પરિચય અને ઉત્પાદન સમાપ્તview
The Apera Instruments EC820 Benchtop Conductivity Meter is a high-precision instrument designed for accurate measurement of Conductivity (EC), Total Dissolved Solids (TDS), Salinity, Resistivity, and temperature. This meter is equipped with advanced features for reliable and stable readings across a wide range of applications.
This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your EC820 meter to ensure optimal performance and longevity.

Figure 1: Apera Instruments EC820 Benchtop Conductivity Meter Kit. The image shows the main meter unit, a flexible electrode arm and holder, and the conductivity electrode submerged in a beaker of liquid.
2. સુરક્ષા સાવચેતીઓ
- Always handle the meter and electrodes with care to prevent damage.
- Do not immerse the main meter unit in water. The unit is IP54 water-resistant, but not submersible.
- ફક્ત પ્રદાન કરેલ પાવર એડેપ્ટરનો ઉપયોગ કરો.
- કેલિબ્રેશન સોલ્યુશન્સ રાખો અનેamples away from children and pets. Follow safety data sheets (SDS) for handling specific chemicals.
- Ensure the meter is placed on a stable, level surface during operation.
- સફાઈ અથવા જાળવણી કરતા પહેલા પાવર ડિસ્કનેક્ટ કરો.
3. પેકેજ સામગ્રી
ખાતરી કરો કે નીચે સૂચિબદ્ધ બધી વસ્તુઓ તમારા પેકેજમાં હાજર છે:
- EC820 પ્રિસિઝન બેન્ચટોપ વાહકતા મીટર
- 2401T-F Platinum Glass-body Conductivity Electrode
- ફ્લેક્સિબલ ઇલેક્ટ્રોડ આર્મ અને હોલ્ડર
- યુએસબી કેબલ
- પીસી-લિંક સોફ્ટવેર ફ્લેશ ડ્રાઇવ
- પાવર એડેપ્ટર (ઇનપુટ: 120V AC 60Hz; આઉટપુટ: 9V 300mA)
- Calibration Solutions:
- 84 µS/cm (1 vial)
- 1413 µS/cm (1 vial)
- 12.88 mS/cm (1 vial)

Figure 2: The 2401T-F Platinum Glass-body Conductivity Electrode, showing its connection cables.
4. સેટઅપ
- Unpack the Meter: પેકેજિંગમાંથી તમામ ઘટકોને કાળજીપૂર્વક દૂર કરો.
- Assemble Electrode Arm: Attach the flexible electrode arm to the meter unit. Ensure it is securely fastened.
- Connect Electrode: Plug the 2401T-F Conductivity Electrode into the designated "COND" port on the back of the meter. Ensure the connection is firm.

Figure 3: Rear panel of the EC820 meter, highlighting the "COND" and "TEMP" ports, along with RS232 and DC 9V power input.
- પાવર કનેક્ટ કરો: Plug the power adapter into the "DC 9V" port on the back of the meter, then connect it to a standard 120V AC 60Hz power outlet.
- પ્રારંભિક પાવર ચાલુ: Press the power button to turn on the meter. The LCD display should illuminate.
5. ઓપરેટિંગ સૂચનાઓ
5.1. માપાંકન
The EC820 meter features 1 to 4 points auto-calibration. Regular calibration ensures accurate measurements.
- Prepare Solutions: Use the provided 84 µS/cm, 1413 µS/cm, and 12.88 mS/cm calibration solutions. Ensure solutions are at room temperature.
- Rinse Electrode: Rinse the conductivity electrode thoroughly with distilled or deionized water before and after each measurement or calibration. Gently blot dry with a lint-free tissue.
- Enter Calibration Mode: With the meter on, press the CAL button. The display will show "CAL" and prompt for the first calibration point.
- First Point Calibration: Immerse the electrode into the 1413 µS/cm standard solution. Wait for the reading to stabilize (indicated by a stable icon on the display). The meter will automatically recognize the solution. Press દાખલ કરો ખાતરી કરવા માટે.
- Subsequent Points (Optional): For higher accuracy, proceed with 84 µS/cm and 12.88 mS/cm solutions following the same procedure. The meter will guide you through the process.
- Exit Calibration: After completing desired calibration points, press the MEAS button to return to measurement mode.
નોંધ: The meter has a self-diagnosis function to help identify and fix common calibration problems. Refer to the on-screen prompts.
5.2. માપન
- Rinse Electrode: ઇલેક્ટ્રોડને નિસ્યંદિત પાણીથી ધોઈ નાખો.
- Immerse Electrode: ઇલેક્ટ્રોડને s માં બોળી દોample solution, ensuring the sensor is fully submerged.
- Wait for Stability: Allow the reading to stabilize. The stable reading icon will appear on the LCD.
- રેકોર્ડ વાંચન: Read the Conductivity (EC), TDS, Salinity, or Resistivity value displayed on the large LCD. Temperature will also be displayed simultaneously.
- એકમો બદલો: દબાવો UNIT button to cycle through different measurement units (e.g., µS/cm, mS/cm, ppm, ppt).
- ડેટા સ્ટોરેજ: The meter supports GLP data management with 500 groups of data storage. Use the M+ / R-M buttons to store and recall data.
- ડેટા નિકાસ: Connect the meter to a PC via the USB cable and use the provided PC-Link software (Windows-based system only) to export data.
6. જાળવણી
- ઇલેક્ટ્રોડ સફાઇ:
- Regularly rinse the electrode with distilled or deionized water.
- For stubborn deposits, refer to the electrode's specific cleaning instructions. Generally, a mild detergent solution or a specific electrode cleaning solution can be used, followed by thorough rinsing.
- Do not scratch or damage the platinum black sensor.
- ઇલેક્ટ્રોડ સંગ્રહ:
- Always store the conductivity electrode in its protective cap filled with a proper electrode storage solution (e.g., 3M KCl solution or Apera Instruments storage solution). Never store dry.
- Meter Cleaning: Wipe the main meter unit with a clean, damp કાપડ ઘર્ષક ક્લીનર્સ અથવા સોલવન્ટનો ઉપયોગ કરશો નહીં.
- સૉફ્ટવેર અપડેટ્સ: Check the Apera Instruments website periodically for any software updates for the PC-Link software.

આકૃતિ 4: ક્લોઝ-અપ view of the platinum glass-body conductivity electrode tip, which requires careful handling and proper storage.
7. મુશ્કેલીનિવારણ
| સમસ્યા | સંભવિત કારણ | ઉકેલ |
|---|---|---|
| મીટર ચાલુ થતું નથી | No power supply; faulty adapter; loose connection. | Check power adapter connection and outlet. Ensure adapter is functional. |
| અસ્થિર વાંચન | Dirty electrode; air bubbles on sensor; incorrect calibration; temperature fluctuations. | Clean electrode; gently tap electrode to remove bubbles; recalibrate meter; ensure sample temperature is stable. |
| માપાંકન ભૂલ | Contaminated calibration solution; incorrect solution used; damaged electrode. | Use fresh calibration solutions; ensure correct solution for calibration point; inspect electrode for damage. |
| No data transfer to PC | Incorrect USB connection; software not installed or running; driver issues. | Verify USB cable connection; ensure PC-Link software is installed and open; check device manager for driver issues. |
8. સ્પષ્ટીકરણો
| પરિમાણ | મૂલ્ય |
|---|---|
| મોડલ નંબર | એઆઈ 532 |
| માપન પરિમાણો | Conductivity (EC), TDS, Salinity, Resistivity, Temperature |
| વાહકતા શ્રેણી | 0 to 2,000 mS |
| ચોકસાઈ | ±0.5% FS |
| માપાંકન પોઈન્ટ | 1 to 4 points auto-calibration (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) |
| તાપમાન વળતર | આપોઆપ તાપમાન વળતર (એટીસી) |
| ડેટા સ્ટોરેજ | ૫૦૦ જૂથો (GLP સુસંગત) |
| કનેક્ટિવિટી | USB for PC data export |
| ડિસ્પ્લે પ્રકાર | મોટી બેકલાઇટ એલસીડી |
| પાવર સપ્લાય | 9V DC, 300mA (120V AC 60Hz adapter included) |
| પ્રવેશ રક્ષણ | IP54 પાણી પ્રતિરોધક |
| પ્રમાણપત્રો | CE, RoHS, ISO 9001:2015 |
| પેકેજ પરિમાણો | 10.63 x 9.88 x 6.61 ઇંચ |
| વજન | 6.5 પાઉન્ડ |
9. વોરંટી અને સપોર્ટ
Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of quality and reliability. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments webસાઇટ
For assistance with troubleshooting, calibration, or general inquiries, please contact Apera Instruments customer service. Contact details can typically be found on their official webસાઇટ અથવા ઉત્પાદન પેકેજિંગમાં.
ઑનલાઇન સંસાધનો: Apera Instruments Store on Amazon
Ask a question about this manual