1. પરિચય

The Extech PH110 Waterproof ExStik pH Meter is designed for accurate pH measurements in various substances. This device features a refillable pH electrode, allowing for extended use and consistent accuracy by replenishing the reference solution. Its robust, waterproof design ensures reliability in diverse environments.

2. મુખ્ય લક્ષણો

  • Refillable pH electrode for extended service life.
  • Analog bargraph display on LCD for trend indication.
  • Waterproof construction to IP57 standard.
  • Automatic 1, 2, or 3 point calibration with buffer solution recognition.
  • Flat Surface Electrode capable of measuring pH in liquids, semi-solids, and solids.

3. પેકેજ સામગ્રી

The Extech PH110 Waterproof ExStik pH Meter package includes:

  • Extech PH110 pH Meter with refillable pH electrode
  • 1.5mL bottle of KCI (Potassium Chloride) solution
  • Two reference junctions
  • Two electrode removal tools
  • રક્ષણાત્મક કેપ
  • Sampલે કપ
  • Four 3V CR-2032 batteries (pre-installed or included separately)
  • 48-inch (1.2m) neck strap

4. સેટઅપ

4.1 બેટરી ઇન્સ્ટોલેશન

  1. Ensure the meter is off.
  2. બેટરી કમ્પાર્ટમેન્ટ શોધો.
  3. Insert four 3V CR-2032 Lithium Metal batteries, observing correct polarity.
  4. બેટરી કમ્પાર્ટમેન્ટને સુરક્ષિત રીતે બંધ કરો.

4.2 Electrode Preparation

  1. ઇલેક્ટ્રોડમાંથી રક્ષણાત્મક કેપ દૂર કરો.
  2. Rinse the electrode tip with distilled water.
  3. If the electrode appears dry, soak it in electrode storage solution or pH 7 buffer for at least 30 minutes before first use.

5. ઓપરેશન

5.1 માપાંકન

Calibration is essential for accurate measurements. The PH110 supports 1, 2, or 3 point calibration and automatically recognizes buffer solutions.

  1. Turn on the meter by pressing the ચાલુ/બંધ બટન
  2. Prepare fresh pH buffer solutions (e.g., pH 4, 7, and 10). These are sold separately.
  3. દબાવો અને પકડી રાખો CAL button until 'CAL' appears on the display.
  4. Immerse the electrode into the first buffer solution (e.g., pH 7). The meter will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
  5. For 2 or 3 point calibration, rinse the electrode with distilled water and immerse it into the next buffer solution (e.g., pH 4, then pH 10). The meter will continue to calibrate automatically.
  6. Ensure the display shows 'CAL' during the calibration process.

5.2 માપ

The flat surface electrode allows for versatile measurements.

  1. After calibration, rinse the electrode with distilled water.
  2. ઇલેક્ટ્રોડને s માં બોળી દોample to be measured. For liquids, ensure the electrode tip is fully submerged. For semi-solids or solids, ensure good contact with the flat surface electrode.
  3. Allow the reading to stabilize on the display. The analog bargraph will indicate trends in acidity or alkalinity.
  4. To switch between pH and temperature display modes, press the મોડ બટન
  5. After measurement, rinse the electrode thoroughly with distilled water and replace the protective cap.
Extech PH110 Waterproof ExStik pH Meter displaying a pH reading.

આકૃતિ 1: The Extech PH110 pH meter, a handheld device with a digital display showing pH and temperature readings. It features three control buttons: MODE, CAL, and ON/OFF.

6. જાળવણી

6.1 Electrode Refilling

The refillable electrode design allows for prolonged accuracy and lifespan.

  1. When the reference solution depletes or accuracy declines, use the provided removal tools to access the reference junctions.
  2. Carefully refill the electrode with the 1.5mL KCI solution.
  3. Ensure the reference junctions are properly re-seated after refilling.
Hands refilling the Extech PH110 pH meter electrode with filling solution.

આકૃતિ 2: એક ક્લોઝ-અપ view of hands refilling the Extech PH110 pH meter's electrode module with a specialized electrode filling solution from a small bottle. This process ensures the meter's continued accuracy and extends electrode life.

6.2 સફાઇ અને સંગ્રહ

  • Always rinse the electrode with distilled water after each use to prevent contamination.
  • The flat surface electrode is designed for easy cleaning. Gently wipe with a soft cloth if necessary.
  • Store the electrode with its protective cap filled with electrode storage solution (or pH 7 buffer if storage solution is unavailable) to keep the sensor hydrated. Do not store dry.

7. મુશ્કેલીનિવારણ

If the meter exhibits inaccurate readings or operational issues, consider the following:

  • અચોક્કસ વાંચન: Recalibrate the meter using fresh buffer solutions. Ensure the electrode is clean and properly hydrated. Check if the reference solution in the electrode needs refilling.
  • ડિસ્પ્લે/પાવર સમસ્યાઓ નથી: Verify that the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
  • ધીમો પ્રતિભાવ: The electrode might be dry or contaminated. Clean and rehydrate the electrode, then recalibrate.

8. સ્પષ્ટીકરણો

સ્પષ્ટીકરણવિગત
ઉત્પાદકએક્સટેક
ભાગ નંબરPH110
વસ્તુનું વજન3.87 ઔંસ
ઉત્પાદન પરિમાણો6.8 x 1.6 x 1.4 ઇંચ
આઇટમ મોડલ નંબરPH110
બેટરીઓ4 Lithium Metal batteries (CR-2032) required (included)
પાવર સ્ત્રોતબેટરી સંચાલિત
વોટરપ્રૂફ રેટિંગIP57 ધોરણ
માપાંકન1, 2, or 3 point automatic buffer recognition
ઇલેક્ટ્રોડ પ્રકારRefillable Flat Surface Electrode

9. વોરંટી માહિતી

Extech provides a full one-year warranty on parts and workmanship for the PH110 pH Meter, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modifications.

10. આધાર

For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the official Extech Instruments website or contact their customer service department. Contact information can typically be found on the manufacturer's packaging or webસાઇટ

સંબંધિત દસ્તાવેજો - PH110

પ્રિview Extech ExStik™ Waterproof pH Meters PH100 & PH110 User Guide
Comprehensive user guide for the Extech ExStik™ Waterproof pH Meters, models PH100 and PH110. Learn about operation, calibration, maintenance, and specifications.
પ્રિview એક્સટેક એક્સસ્ટિક વોટરપ્રૂફ પીએચ મીટર્સ PH100 ​​અને PH110 યુઝર મેન્યુઅલ
એક્સટેક એક્સસ્ટિક વોટરપ્રૂફ પીએચ મીટર, મોડેલ PH100 ​​અને PH110 માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા. આ ઉચ્ચ-ચોકસાઈવાળા પીએચ પરીક્ષણ ઉપકરણો માટે કામગીરી, કેલિબ્રેશન, ઇલેક્ટ્રોડ જાળવણી, બેટરી રિપ્લેસમેન્ટ, સલામતી સાવચેતીઓ, સ્પષ્ટીકરણો અને મુશ્કેલીનિવારણ અંગે વિગતવાર સૂચનાઓ પ્રદાન કરે છે.
પ્રિview Extech ExStik II EC400 Conductivity, TDS, Salinity, Temperature Meter User Manual
Comprehensive user manual for the Extech ExStik II EC400 meter, detailing its features for measuring conductivity, total dissolved solids (TDS), salinity, and temperature. Includes setup, operation, calibration, maintenance, troubleshooting, and specifications.
પ્રિview Extech Comprehensive Catalog: Environmental Meters, Anemometers, and Test Equipment
Explore Extech's extensive range of high-quality environmental meters, thermo-anemometers, gas detectors, water quality testers, sound meters, light meters, and other precision test and measurement instruments designed for industrial, HVAC/R, and professional applications.
પ્રિview Extech PH220 Waterproof Palm pH Meter User Manual
User manual for the Extech PH220 Waterproof Palm pH Meter. Covers introduction, meter description, operation, calibration, measurement, storage, battery replacement, maintenance, troubleshooting, and specifications.
પ્રિview EXTECH 45170 4-in-1 ભેજ, તાપમાન, હવા પ્રવાહ અને પ્રકાશ મીટર વપરાશકર્તા માર્ગદર્શિકા
ભેજ, તાપમાન, હવા પ્રવાહ અને પ્રકાશ માપતા 4-ઇન-1 મીટરવાળા EXTECH 45170 માટે વપરાશકર્તા માર્ગદર્શિકા. તેમાં કામગીરી, સ્પષ્ટીકરણો અને વોરંટી માહિતી શામેલ છે.