HT-Instruments COMBI 420

HT-Instruments Logo

HT-ઇન્સ્ટ્રુમેન્ટ્સ COMBI 420 મલ્ટિફંક્શન VDE 0100 ટેસ્ટર યુઝર મેન્યુઅલ

Model: COMBI 420

1. પરિચય

This user manual provides comprehensive instructions for the safe and effective operation of the HT-Instruments COMBI 420 Multifunction VDE 0100 Tester. The COMBI 420 is an advanced and versatile instrument designed for quick and easy verification of electrical installations. It performs tests in accordance with VDE (EN61557) parts 2, 3, 4, 6, and 7, and includes single-phase network analysis capabilities. Please read this manual thoroughly before using the device to ensure proper functionality and user safety.

2. સલામતી માહિતી

ચેતવણી: Electrical testing can be hazardous. Always follow local safety regulations and procedures. Failure to do so may result in injury or damage to the equipment.

3. ઉત્પાદન ઓવરview

The HT-Instruments COMBI 420 is a robust and user-friendly multifunction tester. It features a large, clear LCD screen with backlight and a graphical help menu for intuitive operation.

HT-Instruments COMBI 420 Multifunction Tester

Figure 3.1: HT-Instruments COMBI 420 Multifunction Tester. The device features a large LCD display, navigation buttons, and input terminals for various measurements.

3.1 મુખ્ય લક્ષણો

3.2 પેકેજ સામગ્રી

The COMBI 420 package includes:

4. સેટઅપ

4.1 બેટરી ઇન્સ્ટોલેશન

The COMBI 420 requires 6 AA alkaline batteries. These are typically included with the device. To install or replace batteries:

  1. ખાતરી કરો કે ઉપકરણ બંધ છે.
  2. ઉપકરણના પાછળના ભાગમાં બેટરી કમ્પાર્ટમેન્ટ શોધો.
  3. કમ્પાર્ટમેન્ટ કવર ખોલો.
  4. Insert 6 AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. બેટરી કમ્પાર્ટમેન્ટ કવર સુરક્ષિત રીતે બંધ કરો.

4.2 Connecting Test Leads and Accessories

Connect the appropriate test leads and accessories to the input terminals on the COMBI 420 based on the measurement you intend to perform. Always ensure connections are secure.

5. ઓપરેટિંગ સૂચનાઓ

5.1 પાવરિંગ ચાલુ/બંધ

દબાવો પાવર button to turn the device on. The device will perform a self-test and display the main menu. To turn off, press and hold the પાવર button, or allow the automatic shutdown feature to activate after a period of inactivity.

5.2 Navigation and Display

Use the directional buttons and the દાખલ કરો button to navigate through the menus and select functions. The large LCD screen displays measurement results, settings, and the graphical help menu. Press ESC/મેનુ to return to the previous menu or access the main menu. The મદદ button provides on-screen assistance for current functions.

૪.૧ માપન કાર્યો

The COMBI 420 offers a wide range of measurement capabilities. Always refer to the on-screen help or specific sections of this manual for detailed connection diagrams and procedures for each test.

  1. Low-Ohm Measurement (Continuity):

    Measures resistance with a test current of >200 mA DC, compliant with VDE 0413 part 4 (EN 61557-4). Used to verify the continuity of protective conductors and equipotential bonding.

  2. ઇન્સ્યુલેશન ટેસ્ટ:

    Performs insulation resistance measurements at 50, 100, 250, 500, or 1000 V DC, compliant with VDE 0413 part 2 (EN 61557-2). Essential for checking the integrity of insulation in electrical systems.

  3. FI (RCD) Test and Analysis:

    Comprehensive testing of Residual Current Devices (RCDs) according to VDE 0413 part 6 (EN 61557-6). Includes trip time, trip current, and contact voltagઇ માપન.

  4. Loop and Network Impedance Measurement:

    Measures loop impedance and network impedance, compliant with VDE 0413 part 3 (EN 61557-3). This is crucial for determining prospective fault current and ensuring proper circuit breaker operation.

  5. Short-Circuit Current Ik Display:

    Displays the calculated prospective short-circuit current (Ik) based on impedance measurements, as per VDE 0413 part 3 (EN 61557-3).

  6. Loop Resistance without RCD Tripping:

    Allows loop resistance measurement in circuits protected by RCDs without causing the RCD to trip, using a low test current.

  7. Rotating Field Direction Measurement:

    Determines the phase sequence (rotating field direction) in three-phase systems, compliant with VDE 0413 part 7 (EN 61557-7). This can be performed even with a single test probe.

  8. Power Measurement and Harmonic Analysis:

    Measures active, reactive, and apparent power, as well as power factor. Performs harmonic analysis of voltage and current up to the 49th harmonic and calculates Total Harmonic Distortion (THD) in percentage.

  9. External Probe Measurements:

    When connected, the device can display readings from external humidity, temperature, light (lux), and sound level probes.

૪.૧ ડેટા સ્ટોરેજ અને ટ્રાન્સફર

The COMBI 420 has an internal memory capable of storing up to 600 measurement values. Use the સાચવો button to store current measurement results. Data can be transferred to a PC using the integrated optical USB interface and the provided Topview સોફ્ટવેર

6. જાળવણી

6.1 સફાઈ

Clean the device regularly with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

6.2 બેટરી રિપ્લેસમેન્ટ

Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for battery installation instructions. Always use new, high-quality AA alkaline batteries.

6.3 માપાંકન

For continued accuracy and compliance, periodic calibration by an authorized service center is recommended. The device is supplied with an ISO 9000 calibration protocol, indicating its initial calibration status.

7. મુશ્કેલીનિવારણ

If you encounter issues with your COMBI 420, try the following basic troubleshooting steps:

For more complex issues, utilize the device's built-in graphical help menu or contact HT-Instruments technical support.

8. સ્પષ્ટીકરણો

લક્ષણસ્પષ્ટીકરણ
મોડલ નંબરકોમબીઆઈ 420
ઉત્પાદકHT-Instruments
ઉત્પાદનના પરિમાણો (L x W x H)૧૦ x ૧૦ x ૧૦ સેમી (આશરે ૩.૯૪ x ૩.૯૪ x ૩.૯૪ ઇંચ)
વજન3 કિલો (આશરે 6.6 પાઉન્ડ)
પાવર સ્ત્રોતBattery-Powered (6 AA batteries required, included)
સલામતી અનુપાલનIEC-1010-1, CAT III 415 V
માપન ધોરણોVDE (EN61557) parts 2, 3, 4, 6, 7
આંતરિક મેમરી600 measurement values
ઈન્ટરફેસઓપ્ટિકલ યુએસબી
સમાવાયેલ ઘટકોટોચview software, USB cable, storage bag, measurement cable with earthed plug, 3 safety test leads, 2 test probes, 3 crocodile clips, batteries, user manual, ISO 9000 calibration protocol

9. વોરંટી અને સપોર્ટ

HT-Instruments products are manufactured to high quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official HT-Instruments website. For technical support, service, or inquiries regarding calibration, please contact your local HT-Instruments distributor or customer service department.

સંબંધિત દસ્તાવેજો - કોમબીઆઈ 420

પ્રિview COMBI521 મલ્ટિફંક્શન ટેસ્ટર: ઇલેક્ટ્રિકલ સેફ્ટી, પાવર ક્વોલિટી અને EVSE ટેસ્ટિંગ
HT ઇન્સ્ટ્રુમેન્ટ્સ COMBI521 મલ્ટિફંક્શન ટેસ્ટર માટે વ્યાપક ટેકનિકલ સ્પષ્ટીકરણો, જેમાં ઇલેક્ટ્રિકલ ઇન્સ્ટોલેશન સલામતી પરીક્ષણો, પાવર ગુણવત્તા વિશ્લેષણ અને EVSE સલામતી પરીક્ષણો માટે તેની ક્ષમતાઓનું વિગતવાર વર્ણન છે. માપન કાર્યો, વિગતવાર ટેકનિકલ ડેટા, સામાન્ય સ્પષ્ટીકરણો અને પાલન માહિતી શામેલ છે.
પ્રિview HT Instruments PV-ISOTEST User Manual
Comprehensive user manual for the HT Instruments PV-ISOTEST, detailing safety precautions, instrument functions, operating instructions, technical specifications, and troubleshooting for photovoltaic insulation testing.
પ્રિview HT Instruments M70 Handheld Insulation/Continuity Meter Specifications and Features
Detailed specifications, features, and reference standards for the HT Instruments M70 handheld insulation and continuity meter, capable of up to 1000VDC. Includes information on electrical tests, power, and operating conditions, along with services offered by EURO-INDEX.
પ્રિview HT Instruments NEPTUNE Multifunction Professional Safety Multimeter Datasheet
Comprehensive datasheet for the HT Instruments NEPTUNE, a professional safety multimeter. Details electrical specifications, features, power supply, environmental conditions, and compliance information.
પ્રિview HT Instruments HT7 Digital Voltage ટેસ્ટર યુઝર મેન્યુઅલ
Comprehensive user manual for the HT Instruments HT7 digital voltage tester, covering safety instructions, operating procedures, technical specifications, and maintenance for safe and effective use.
પ્રિview HT ઇન્સ્ટ્રુમેન્ટ્સ MACROTESTG3 પ્રોફેશનલ ઇન્સ્ટોલેશન સેફ્ટી ટેસ્ટર - સ્પષ્ટીકરણો અને સુવિધાઓ
વિગતવાર ટેકનિકલ સ્પષ્ટીકરણો, વિદ્યુત પરિમાણો, RCD પરીક્ષણ ક્ષમતાઓ, લૂપ અવબાધ, ઇન્સ્યુલેશન પ્રતિકાર, વોલ્યુમtagHT ઇન્સ્ટ્રુમેન્ટ્સ MACROTESTG3 પ્રોફેશનલ ઇન્સ્ટોલેશન સેફ્ટી ટેસ્ટરના e, કરંટ, પાવર ફેક્ટર અને હાર્મોનિક્સ માપન.