Trane PSE-T19

Trane Furnace Flame Sensor PSE-T19 Instruction Manual

Model: PSE-T19 (Part Number: SEN01114_v4)

1. પરિચય

This manual provides essential information for the proper installation, operation, maintenance, and troubleshooting of the Trane Furnace Flame Sensor, model PSE-T19. This component is a critical safety device designed to ensure the safe and efficient operation of your furnace. Please read this manual thoroughly before attempting any procedures.

2. સલામતી માહિતી

ચેતવણી: અયોગ્ય સ્થાપન, ગોઠવણ, ફેરફાર, સેવા અથવા જાળવણી મિલકતને નુકસાન, ઈજા અથવા મૃત્યુનું કારણ બની શકે છે. આ સાધનોને ઇન્સ્ટોલ અથવા સર્વિસ કરતા પહેલા ઇન્સ્ટોલેશન, ઑપરેટિંગ અને જાળવણી સૂચનાઓને સારી રીતે વાંચો.

  • Always disconnect electrical power to the furnace before performing any service or maintenance.
  • Working with gas appliances can be hazardous. If you are not qualified to perform these procedures, contact a certified HVAC technician.
  • યોગ્ય વ્યક્તિગત રક્ષણાત્મક ઉપકરણો (PPE) પહેરો, જેમ કે મોજા અને આંખનું રક્ષણ.
  • Ensure all gas connections are properly sealed and tested for leaks after any work involving gas lines.
  • કોઈપણ સુરક્ષા ઉપકરણોને બાયપાસ કરશો નહીં.

3. ઉત્પાદન ઓવરview

The flame sensor is a safety device in a gas furnace that detects the presence of a flame in the burner assembly. If the sensor does not detect a flame after the gas valve opens, it signals the furnace control board to shut off the gas supply, preventing unburnt gas from accumulating. This specific sensor is an upgraded replacement for Trane part number SEN01114.

Image of the Trane Furnace Flame Sensor PSE-T19

Figure 1: Trane Furnace Flame Sensor PSE-T19
This image displays the Trane Furnace Flame Sensor PSE-T19. It features a white ceramic insulator body, a metal mounting bracket with a screw hole, and a metal rod that extends into the flame path to detect the presence of a flame.

4. સેટઅપ અને ઇન્સ્ટોલેશન

Installation of the flame sensor should only be performed by a qualified technician. The following steps are for informational purposes only.

  1. પાવર ડિસ્કનેક્ટ કરો: Turn off all electrical power to the furnace at the main service panel.
  2. સેન્સર શોધો: Identify the existing flame sensor. It is typically a single metal rod positioned in the flame path of the burner assembly, often secured by one screw.
  3. જૂનું સેન્સર દૂર કરો: Carefully disconnect the wire leading to the sensor. Remove the screw holding the sensor in place and gently pull the old sensor out.
  4. નવું સેન્સર ઇન્સ્ટોલ કરો: Insert the new Trane PSE-T19 flame sensor into the same position. Ensure the metal rod is correctly positioned to be enveloped by the flame during operation. Secure it with the mounting screw.
  5. વાયરિંગ કનેક્ટ કરો: Reconnect the wire to the new flame sensor. Ensure the connection is secure.
  6. પાવર પુન Restસ્થાપિત કરો: ભઠ્ઠીમાં ઇલેક્ટ્રિક પાવર ચાલુ કરો.
  7. ટેસ્ટ ઓપરેશન: Initiate a heating cycle and observe the furnace's ignition sequence. The main burners should ignite and remain lit.

5. સંચાલન સિદ્ધાંતો

When the furnace calls for heat, the igniter heats up, and the gas valve opens. As the gas ignites, the flame sensor, which is a small metal rod, becomes exposed to the flame. The flame rectifies a small alternating current (AC) into a direct current (DC) signal. This DC signal is sent to the furnace's control board, confirming the presence of a flame. If the control board does not receive this signal within a few seconds of ignition, it will shut off the gas supply as a safety measure, preventing unburnt gas from accumulating in the combustion chamber.

6. જાળવણી

Regular maintenance of the flame sensor is crucial for reliable furnace operation. A dirty flame sensor is a common cause of furnace malfunctions.

  • સફાઈ: Annually, or if experiencing ignition issues, carefully remove the flame sensor. Use fine-grit sandpaper or steel wool to gently clean off any carbon buildup or oxidation from the ceramic insulator and the metal rod. Do not use harsh chemicals or abrasive cleaners that could damage the sensor.
  • નિરીક્ષણ: While cleaning, inspect the sensor for any signs of physical damage, such as cracks in the ceramic, corrosion, or a bent rod. Replace the sensor if any damage is observed.
  • પુનઃસ્થાપન: Reinstall the cleaned sensor, ensuring it is securely mounted and the wire connection is tight.

7. મુશ્કેલીનિવારણ

If your furnace is experiencing issues related to ignition or short cycling, the flame sensor may be a contributing factor.

  • Furnace Ignites, then Shuts Off (Short Cycling): This is a classic symptom of a dirty or faulty flame sensor. The sensor detects the flame initially but then loses the signal, causing the furnace to shut down.
  • Furnace Fails to Ignite: While many factors can cause this, a completely failed flame sensor can prevent the furnace from even attempting to keep the gas valve open.

મુશ્કેલીનિવારણ પગલાં:

  1. Clean the Flame Sensor: Follow the cleaning instructions in Section 6. This resolves most flame sensor-related issues.
  2. વાયરિંગ તપાસો: Ensure the wire connecting the flame sensor to the control board is secure and free from damage.
  3. નુકસાન માટે તપાસ કરો: Look for any visible damage to the sensor itself.
  4. Test for Continuity (Advanced): A qualified technician can use a multimeter to test the sensor's continuity and signal output.
  5. સેન્સર બદલો: If cleaning and inspection do not resolve the issue, and the sensor is suspected to be faulty, replace it with a new Trane PSE-T19 or equivalent part.

8. સ્પષ્ટીકરણો

વિશેષતામૂલ્ય
મોડલ નંબરPSE-T19 (SEN01114_v4)
ઉત્પાદકટ્રેન
ઉત્પાદન પરિમાણો6 x 6 x 6 ઇંચ
વસ્તુનું વજન0.53 ઔંસ
ASINB00ECEERIG

9. વોરંટી માહિતી

Warranty coverage for the Trane Furnace Flame Sensor PSE-T19 is typically provided by the seller or manufacturer at the time of purchase. Please refer to your purchase documentation or contact the original point of sale for specific warranty terms and conditions.

10. આધાર

For technical assistance, installation guidance, or troubleshooting beyond the scope of this manual, please contact the seller or a qualified HVAC professional. Ensure you have your product model number (PSE-T19 or SEN01114_v4) and purchase details available when seeking support.

સંબંધિત દસ્તાવેજો - PSE-T19

પ્રિview ટ્રેન XL 80 અપફ્લો/ડાઉનફ્લો હોરિઝોન્ટલ ગેસ-ફાયર્ડ ફર્નેસ: સ્પષ્ટીકરણો અને સુવિધાઓ
ટ્રેન XL 80 શ્રેણીના ગેસ-ફાયર્ડ ફર્નેસ (TUD2 અને TDD2 મોડેલ્સ) માટે વ્યાપક માર્ગદર્શિકા, જેમાં અપફ્લો, ડાઉનફ્લો અને હોરીઝોન્ટલ ઇન્સ્ટોલેશન માટે સુવિધાઓ, પ્રદર્શન ડેટા, ઇલેક્ટ્રિકલ સ્પષ્ટીકરણો અને પરિમાણોની વિગતો આપવામાં આવી છે.
પ્રિview ટ્રેન અને અમેરિકન સ્ટાન્ડર્ડ S8 સિરીઝ ગેસ ફર્નેસ ઇન્સ્ટોલેશન, ઓપરેશન અને મેઇન્ટેનન્સ મેન્યુઅલ
ટ્રેન અને અમેરિકન સ્ટાન્ડર્ડ S8 સિરીઝ અપફ્લો/ડાઉનફ્લો/હોરિઝોન્ટલ ગેસ-ફાયર્ડ 1-S ના ઇન્સ્ટોલેશન, સંચાલન અને જાળવણી માટે વ્યાપક માર્ગદર્શિકાtage અને 2-Stagઉચ્ચ કાર્યક્ષમતા મોટર સાથે પ્રેરિત ડ્રાફ્ટ ભઠ્ઠીઓ. સલામતી ચેતવણીઓ, સ્પષ્ટીકરણો, વાયરિંગ ડાયાગ્રામ અને મુશ્કેલીનિવારણ શામેલ છે.
પ્રિview Trane XT95 High Efficiency Gas Furnace: Specifications and Features
Detailed product data, features, benefits, specifications, performance data, electrical wiring diagrams, and dimensions for the Trane XT95 series of high-efficiency, single-stage, fan-assisted, condensing, direct vent gas-fired furnaces.
પ્રિview Trane & American Standard IFC Board Failure Service Bulletin - MANDATORY Rework
Official service bulletin from Trane and American Standard regarding Integrated Furnace Control (IFC) board failures in specific furnace models. Details error code 5, affected models, and mandatory rework instructions.
પ્રિview Trane S9V2 Series Gas Furnace: Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining Trane and American Standard S9V2 series 2-stage condensing variable speed gas furnaces. Covers safety, installation procedures, specifications, and troubleshooting.
પ્રિview Trane S9V2 Series Two Stage Condensing Gas Fired Furnace Product Data
Detailed product data and specifications for the Trane S9V2 Series Two Stage Condensing Gas Fired Furnace, covering features, benefits, model variations, technical specifications, and airflow performance tables.