Uponor 1013006

Uponor Thermal Actuator ST230, 230V, Model 1013006 Instruction Manual

1. પરિચય

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Uponor Thermal Actuator ST230, 230V, Model 1013006. Please read these instructions carefully before proceeding with installation or use. Retain this manual for future reference.

2. ઉત્પાદન ઓવરview

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for controlling the return valves on Uponor Vario S manifolds in underfloor heating systems. It operates on 230 Volts and features a screw connection IG M 30 x 1.5, a stroke indicator, and a 1.0-meter connection cable with wire end ferrules. The unit is splash-proof with an IP54 rating and is CE and RoHS certified.

Uponor Thermal Actuator ST230, 230V, Model 1013006

આકૃતિ 2.1: Uponor Thermal Actuator ST230, 230V, Model 1013006. This image shows the blue housing of the actuator with the Uponor logo and the grey screw connection base.

3. સલામતી માહિતી

  • Installation and electrical connections must be performed by a qualified electrician or authorized personnel in accordance with local regulations and standards.
  • કોઈપણ ઇન્સ્ટોલેશન, જાળવણી અથવા મુશ્કેલીનિવારણ કરતા પહેલા ખાતરી કરો કે મુખ્ય પાવર સપ્લાય ડિસ્કનેક્ટ થયેલ છે.
  • Do not open the actuator housing. There are no user-serviceable parts inside.
  • Protect the device from direct water spray or immersion, despite its splash-proof rating.
  • Use only genuine Uponor components and accessories.

4. સેટઅપ અને ઇન્સ્ટોલેશન

The thermal actuator is designed for easy mounting on Uponor Vario S manifold return valves. Follow these steps for proper installation:

  1. Ensure the heating system is depressurized and the manifold valves are in the correct position for actuator mounting.
  2. Carefully screw the actuator onto the valve connection (IG M 30 x 1.5) by hand until it is securely fastened. Do not overtighten.
  3. Connect the 230V electrical cable to the appropriate control unit or thermostat terminals. The cable is 0.75 mm² x 1.0 m and comes with wire end ferrules for secure connection.
  4. Verify all connections are secure and correctly wired according to the system's electrical diagram.
Diagram of Uponor Thermal Actuator with cable

આકૃતિ 4.1: Diagram showing the Uponor Thermal Actuator with its integrated connection cable. This illustrates the actuator's form factor and cable exit point.

Dimensional drawing of Uponor Thermal Actuator

આકૃતિ 4.2: Dimensional drawing of the Uponor Thermal Actuator, indicating key measurements (do, h, G) for installation planning. 'do' represents the outer diameter, 'h' the height, and 'G' the thread size.

5. ઓપરેટિંગ સૂચનાઓ

The Uponor Thermal Actuator operates automatically in conjunction with a room thermostat or heating control system. When the control system signals a demand for heat, the actuator receives power, causing its internal element to expand and open the valve. When the heat demand is met, power is removed, and the actuator cools, closing the valve.

  • Stroke Indicator: The actuator is equipped with a stroke indicator, typically a small pin or window, which visually confirms the valve's open or closed position. Observe this indicator to verify proper operation.
  • પ્રારંભિક કામગીરી: After installation and power-up, allow a short period for the actuator to respond to the control signal and fully open or close the valve.

6. જાળવણી

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for maintenance-free operation. No regular servicing or lubrication is required.

  • Keep the exterior of the actuator clean and free from dust or debris. Use a soft, dry cloth for cleaning.
  • ઘર્ષક ક્લીનર્સ અથવા સોલવન્ટનો ઉપયોગ કરશો નહીં.
  • Periodically check the electrical connections for any signs of wear or damage.

7. મુશ્કેલીનિવારણ

If the thermal actuator is not functioning as expected, consider the following:

  • Actuator not opening/closing:
    • Check if the control system (thermostat) is calling for heat.
    • Verify that the actuator is receiving 230V power.
    • Ensure electrical connections are secure and correct.
    • Confirm the actuator is correctly screwed onto the valve.
  • No visible movement of stroke indicator:
    • Allow sufficient time for the actuator to react (thermal actuators have a delay).
    • Check power supply and control signal.

If issues persist after checking these points, contact qualified service personnel.

8. સ્પષ્ટીકરણો

Uponor Thermal Actuator ST230, 230V, Model 1013006 Technical Data Sheet

આકૃતિ 8.1: Technical data sheet for the Uponor Thermal Actuator ST230, 230V, Model 1013006, providing detailed specifications and contact information.

સ્પષ્ટીકરણમૂલ્ય
બ્રાન્ડઅપોનોર
મોડલ નંબર1013006
ઉત્પાદકઅપોનોર
ઉત્પાદનના પરિમાણો (L x W x H)5 x 5 x 7.5 સેમી
વજન120 ગ્રામ
ભાગtage230 વોલ્ટ
મહત્તમ વોલ્યુમtage230 વોલ્ટ
કનેક્ટર પ્રકારકોદાળી
સંપર્ક સામગ્રીસ્ટેનલેસ સ્ટીલ
ઇન્સ્યુલેશન સામગ્રીપોલિઓલેફિન
ટર્મિનલ પ્રકારSpade Terminal
સુસંગત સ્પષ્ટીકરણોCE, RoHS
મૂળ દેશજર્મની
આંતરરાષ્ટ્રીય લેખ કોડ (EAN)04021598002937
કનેક્શન કેબલ0.75 mm² x 1.0 m, without plug, with wire end ferrules
રક્ષણ વર્ગIP54 (સ્પ્લેશ-પ્રૂફ)
વાલ્વ કનેક્શનScrew connection IG M 30 x 1.5
લક્ષણસ્ટ્રોક સૂચક

9. વોરંટી અને સપોર્ટ

Uponor products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Uponor directly. Information regarding spare parts availability is not provided in the product specifications.

સંપર્ક માહિતી:

અપોનોર જીએમબીએચ

ઇન્ડસ્ટ્રીઝ 56

97437 Hassfurt

જર્મની

ટેલિફોન: +4932210090856

ઈમેલ: Kundenservice@uponor.com

Webસાઇટ: www.uponor.com/de-de

સંબંધિત દસ્તાવેજો - 1013006

પ્રિview Uponor Underfloor Heating and Cooling: Planning Information Guide
This comprehensive planning guide from Uponor details underfloor heating and cooling systems, covering technical specifications, design criteria, installation procedures, and hydraulic balancing for optimal climate control solutions.
પ્રિview Uponor Classic Installation Manual
This manual provides detailed installation instructions for the Uponor Classic system, including pipe laying, manifold connection, and pressure testing. It covers essential steps for a successful and efficient installation of the Uponor Classic floor heating system.
પ્રિview Uponor Vario / Vario PLUS Actuator Installation and Technical Manual
Comprehensive guide to the Uponor Vario and Vario PLUS actuators, covering installation, operation, features like 'First-Open', and detailed technical specifications for HVAC systems.
પ્રિview Uponor Vario Retrofit Actuator: Installation Guide and Technical Specifications
Comprehensive guide to installing and operating the Uponor Vario retrofit actuator, including detailed technical specifications, compatibility information, and safety instructions for HVAC systems.
પ્રિview Uponor Siccus Mini: Dry Underfloor Heating and Cooling System Technical Specifications
Comprehensive technical information for the Uponor Siccus Mini low-height dry underfloor heating and cooling system. Covers system description, benefits, components, planning, installation, and detailed technical specifications for residential modernization.
પ્રિview Uponor Combi Port E-Hybrid Quick Guide - Installation and Operation
This quick guide provides essential information for the installation and operation of the Uponor Combi Port E-Hybrid heat interface unit. It covers general safety, component identification, hydraulic and electrical installation, filling, flushing, testing, and visual inspection procedures.