This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Sloan 186-0.125 Exposed Manual Urinal Flushometer. This product is designed for commercial urinal applications, offering reliable and water-efficient flushing.
Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the unit. Retain this manual for future reference.
2. સલામતી માહિતી
- Always shut off the main water supply before beginning any installation or maintenance.
- Wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, during installation and maintenance.
- પાણીના નુકસાનને રોકવા માટે ખાતરી કરો કે બધા જોડાણો સુરક્ષિત અને લીક-મુક્ત છે.
- જો તમને કોઈ પણ પગલા વિશે ખાતરી ન હોય, તો લાયક પ્લમ્બરની સલાહ લો.
- આ ઉત્પાદનમાં એવા રસાયણો છે જે કેલિફોર્નિયા રાજ્યમાં જાણીતા છે જે કેન્સર અને જન્મજાત ખામીઓ અથવા અન્ય પ્રજનન નુકસાન પહોંચાડે છે (પ્રસ્તાવના 65 ચેતવણી).
3. પેકેજ સામગ્રી
ઇન્સ્ટોલેશન શરૂ કરતા પહેલા ખાતરી કરો કે બધા ઘટકો હાજર છે:
- Sloan 186-0.125 Exposed Manual Urinal Flushometer unit
- Sweat solder adapter and cover tube
- 3/4" I.P.S. screwdriver Bak-Chek angle stop with vandal resistant stop cap
- High back pressure vacuum breaker (15") with flush connection
- Installation hardware (gaskets, nuts, etc.)

છબી ૧: મુખ્ય view of the Sloan 186-0.125 Exposed Manual Urinal Flushometer, showing its polished chrome finish and components.
4. સ્પષ્ટીકરણો
| લક્ષણ | વિગત |
|---|---|
| મોડલ નંબર | 3782643 |
| ફ્લશ વોલ્યુમ | 0.125 Gallons Per Flush (GPF) |
| સામગ્રી | પિત્તળ |
| બાહ્ય સમાપ્ત | પોલિશ્ડ ક્રોમ |
| ઇનલેટ કનેક્શન કદ | 0.75 ઇંચ |
| ઇનલેટ કનેક્શનનો પ્રકાર | Sweat Adaptor |
| આઉટલેટ કનેક્શન પ્રકાર | Fixture Top Spud |
| મહત્તમ ઓપરેટિંગ દબાણ | 80 PSI |
| એડીએ સુસંગત | હા |
| પરિમાણો (L x W x H) | 9.75 x 9.13 x 4.38 ઇંચ |
| વસ્તુનું વજન | 6.09 પાઉન્ડ |
૫. ઇન્સ્ટોલેશન (સેટઅપ)
Follow these steps for proper installation of the flushometer:
- પાણી પુરવઠો તૈયાર કરો: Ensure the main water supply to the urinal is turned off. Flush the line to clear any debris.
- Install Angle Stop: Install the 3/4" I.P.S. screwdriver Bak-Chek angle stop with the vandal resistant stop cap onto the water supply pipe. Ensure it is securely tightened.
- Connect Flushometer Body: Attach the flushometer body to the angle stop. Use the sweat solder adapter and cover tube for a secure and leak-free connection.
- Install Vacuum Breaker: Connect the high back pressure vacuum breaker (15") to the flushometer outlet and then to the urinal's top spud. Ensure all gaskets are properly seated and connections are hand-tightened, then use a wrench for a final snug fit.
- Adjust Flushometer: The flushometer is designed with no external volume adjustment. The 0.125 GPF is factory set.
- લીક્સ માટે તપાસો: Slowly turn on the main water supply. Inspect all connections for leaks. Tighten any leaking connections as necessary.
- Test Flush: Activate the flushometer handle to ensure proper operation and water flow to the urinal.

છબી ૪.૨: વિસ્ફોટ થયો view or diagram of a Sloan flushometer, illustrating various components and their assembly points for installation.
6. ઓપરેશન
The Sloan 186-0.125 Exposed Manual Urinal Flushometer operates with a simple manual action:
- To flush the urinal, press down firmly on the metal oscillating handle.
- The handle is designed with a non-hold-open feature, meaning it will return to its original position automatically after a flush cycle, preventing continuous water flow and promoting water conservation.
- The flushometer delivers a precise 0.125 GPF (Gallons Per Flush) for efficient urinal rinsing.

છબી 6.1: ક્લોઝ-અપ view of the Sloan flushometer, highlighting the manual oscillating handle used for operation.
7. જાળવણી
Regular maintenance ensures optimal performance and extends the life of your flushometer:
- સફાઈ: Clean the exterior polished chrome finish with a soft cloth and mild, non-abrasive cleaner. Avoid harsh chemicals or abrasive pads, which can damage the finish.
- Diaphragm and Seals: The diaphragm, handle packing, and vacuum breaker components are molded from PERMEX rubber compound. This material is resistant to chloramine, enhancing durability. Periodically inspect these components for wear or damage. Replace if necessary.
- Bypass and Vortex Cleansing: The dual filtered bypass and vortex cleansing action help maintain the flushometer's efficiency. If flushing performance degrades, internal components may require inspection and cleaning by a qualified technician.
- Angle Stop: The Bak-Chek angle stop allows for water shut-off to the flushometer for maintenance without affecting the main water supply. Ensure it functions correctly.
8. મુશ્કેલીનિવારણ
સામાન્ય સમસ્યાઓ અને તેમના સંભવિત ઉકેલો માટે નીચેના કોષ્ટકનો સંદર્ભ લો:
| સમસ્યા | સંભવિત કારણ | ઉકેલ |
|---|---|---|
| Low flush volume or weak flush |
|
|
| સતત પાણીનો પ્રવાહ |
|
|
| Handle does not return to original position |
|
|
| કનેક્શનમાંથી લીક |
|
|
For issues not listed or if troubleshooting steps do not resolve the problem, contact Sloan customer support or a qualified plumbing professional.
9. વોરંટી અને સપોર્ટ
Sloan products are manufactured to high standards and are backed by a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or visit the official Sloan webસાઇટ
For technical support, replacement parts, or further assistance, please contact Sloan customer service. Contact information can typically be found on the Sloan webસાઇટ અથવા ઉત્પાદન પેકેજિંગ.
ઑનલાઇન સંસાધનો: વધારાની માહિતી અને સંસાધનો માટે, મુલાકાત લો Sloan Brand Store on Amazon.