1. પરિચય
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo JSWM2CX self-priming water pump. Please read these instructions carefully before using the product and retain them for future reference.
2. સલામતી માહિતી
Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This pump operates with electricity and water, which can be hazardous if not handled correctly.
- Ensure the power supply matches the pump's specifications (220V, single-phase).
- Always disconnect power before performing any maintenance or installation work.
- જો પાવર કોર્ડ અથવા પ્લગ ક્ષતિગ્રસ્ત હોય તો પંપ ચલાવશો નહીં.
- Install the pump in a dry, well-ventilated area, protected from direct weather exposure.
- વિદ્યુત જોડાણો માટે યોગ્ય ગ્રાઉન્ડિંગની ખાતરી કરો.
- Do not pump flammable, corrosive, or explosive liquids. This pump is designed for clean water with low sediment content.
- પંપ ચલાવતી વખતે બાળકો અને અનધિકૃત કર્મચારીઓને તેનાથી દૂર રાખો.
3. ઉત્પાદન ઓવરview અને લક્ષણો
The Pedrollo JSWM2CX is a self-priming surface water pump designed for domestic and professional applications requiring a 220V single-phase electrical supply. It is particularly recommended for drawing clear water from wells or other sources where the suction depth is less than 9 meters. This pump can also be integrated into a water tank system or used with a pressure booster.
મુખ્ય લાક્ષણિકતાઓમાં શામેલ છે:
- Self-Priming Capability: Efficiently draws water from depths up to 9 meters.
- Noryl Impeller: Ensures reliable and quiet operation with an excellent flow rate to pressure ratio.
- મજબૂત બાંધકામ: Features a cast iron pump body, aluminum lantern, and stainless steel pump base.
- કાર્યક્ષમ મોટર: 0.75 kW, 2900 rpm, IE3 class motor for high efficiency and low power consumption.
- Integrated Thermal Protection: For the 220V single-phase motor, protecting the pump from unexpected startups or overheating.
- ઉચ્ચ પ્રવાહ દર: Up to 4.2 cubic meters per hour.
- મહત્તમ હેડ: Up to 50 HMT (Hydraulic Metre Total).

4. સ્પષ્ટીકરણો
| ઉત્પાદક | પેડ્રોલો |
| મોડલ સંદર્ભ | JSWM2CX |
| રંગ | વાદળી |
| સામગ્રી | Cast Iron (Pump Body), Noryl (Impeller, Diffuser/Ejector), Aluminum (Lantern), Stainless Steel (Pump Base, Motor Shaft) |
| પાવર પ્રકાર | ઇલેક્ટ્રિક કેબલ |
| ભાગtage | 220 Volts (AC), Single-phase |
| શક્તિ | 0.75 kW |
| મોટર સ્પીડ | 2900 આરપીએમ |
| મહત્તમ પ્રવાહ દર | 4.2 Cubic Meters per Hour |
| મેક્સ સક્શન હેડ | 9 મીટર |
| Max Service Pressure | 6 બાર |
| પ્રોટેક્શન ઇન્ડેક્સ | IPX4 |
| ઇન્સ્યુલેશન વર્ગ | F |
| સતત સેવા | S1 |
| Motor Class | IE3 (High Efficiency) |
| Motor Shaft Material | Stainless Steel EN 10088-3 - 1.4104 |

5. સ્થાપન અને સેટઅપ
Proper installation is crucial for the pump's performance and longevity. Refer to the diagram below for typical installation exampલેસ
- સ્થાન: Install the pump in a dry, frost-free, and well-ventilated area. Ensure it is protected from direct sunlight and rain.
- માઉન્ટ કરવાનું: Secure the pump to a stable, level surface to minimize vibration.
- સક્શન લાઇન: The pump is self-priming for suction depths up to 9 meters. Ensure the suction line is airtight and has a foot valve with a strainer at the end to prevent debris from entering the pump. The diameter of the suction pipe should be adequate for the required flow rate.
- Delivery Line: Connect the delivery pipe to the pump outlet. It is recommended to install a check valve and a shut-off valve on the delivery side.
- ઇલેક્ટ્રિકલ કનેક્શન: Connect the pump to a dedicated 220V single-phase power supply with appropriate circuit protection. Ensure proper grounding. The integrated thermal protection will safeguard the motor.
- પ્રિમિંગ: Before first use, or if the pump has run dry, fill the pump casing completely with water through the priming port until it overflows. Close the priming port securely.

6. ઓપરેશન
The Pedrollo JSWM2CX pump is designed for handling clean liquids with low sediment content. It is suitable for various applications:
- Pressurized Water Distribution: Ideal for supplying water under pressure, often in conjunction with a bladder tank.
- Garden Irrigation: Provides efficient water supply for garden watering systems.
- Washing Applications: Suitable for washing vehicles, terraces, and other surfaces.
- Sanitary System Supply: Can be used to feed domestic sanitary installations.
- Other Specific Applications: Designed for domestic, agricultural, industrial, and horticultural uses.
પંપ શરૂ કરી રહ્યા છીએ: After ensuring the pump is properly primed and all connections are secure, switch on the power supply. The pump should start operating and deliver water. If the pump does not start or fails to deliver water, refer to the troubleshooting section.
પ્રદર્શન: The pump's performance (flow rate vs. head) can be referenced in the performance curve diagram below.

7. જાળવણી
Regular maintenance ensures optimal performance and extends the pump's lifespan.
- નિયમિત તપાસ: Periodically check for leaks, unusual noises, or vibrations.
- સ્વચ્છતા: Keep the pump and its surroundings clean and free from debris. Ensure the motor's cooling fins are not obstructed.
- ફૂટ વાલ્વ/સ્ટ્રેનર: Inspect and clean the foot valve strainer on the suction line regularly to prevent blockages.
- વિન્ટરાઇઝેશન: In areas subject to freezing temperatures, drain the pump completely to prevent damage from ice expansion. Disconnect the pump from the power supply and open all drain plugs. Store in a dry, frost-free location.
- યાંત્રિક સીલ: The mechanical seal is a wear part. If persistent leaks occur from the motor side, the seal may need replacement by a qualified technician.
8. મુશ્કેલીનિવારણ
તકનીકી સપોર્ટનો સંપર્ક કરતા પહેલા, પુનઃview નીચેના સામાન્ય મુદ્દાઓ અને ઉકેલો:
| સમસ્યા | સંભવિત કારણ | ઉકેલ |
|---|---|---|
| પંપ ચાલુ થતો નથી. | No power supply; tripped circuit breaker; motor thermal protection activated; seized impeller. | Check power connection and circuit breaker; allow motor to cool down; inspect impeller for obstructions and manually turn if possible (with power off). |
| પંપ ચાલે છે પણ પાણી પહોંચાડતો નથી કે ઓછો પ્રવાહ આપતો નથી. | Pump not primed; air leak in suction line; clogged foot valve/strainer; suction lift too high; impeller damaged. | Re-prime the pump; check all suction line connections for leaks; clean foot valve strainer; ensure suction depth is within limits (max 9m); inspect impeller. |
| અતિશય અવાજ અથવા કંપન. | Air in the pump/suction line; cavitation; loose mounting; worn bearings. | Ensure pump is fully primed and suction line is airtight; check for obstructions in suction; tighten mounting bolts; contact service for bearing inspection. |
| Water leaking from pump. | Loose connections; damaged mechanical seal; cracked casing. | Tighten all pipe connections; mechanical seal replacement by qualified personnel; inspect casinનુકસાન માટે g. |
For issues not listed or if solutions do not resolve the problem, please contact a qualified technician or Pedrollo customer support.
9. વોરંટી અને સપોર્ટ
Specific warranty details are typically provided with your purchase documentation. Please refer to the warranty card or contact your retailer for information regarding the warranty period and terms.
For technical assistance, spare parts, or service, please contact your authorized Pedrollo dealer or the manufacturer's customer service department. When contacting support, please have your pump's model number (JSWM2CX) and serial number (if applicable) readily available.
ઉત્પાદક: પેડ્રોલો
મોડલ: JSWM2CX