1. પરિચય
This manual provides essential information for the safe and efficient operation of your LEESKY 2000W Pure Sine Wave Power Inverter. Please read these instructions thoroughly before installation and use. Retain this manual for future reference.
પેકેજ સામગ્રી:
- 1x LEESKY 2000 Watt Pure Sine Wave Power Inverter
- 2x Battery Cables (black and red)
- 1x 15ft Remote Controller
- 1x Earth Wire
- 8x Shockproof Pads
- ૧x વપરાશકર્તા માર્ગદર્શિકા (આ દસ્તાવેજ)

Image 1.1: The LEESKY 2000W Pure Sine Wave Power Inverter with its included battery cables, remote controller, and GFCI outlet.
2. સલામતી માહિતી
Observe the following safety precautions to prevent injury or damage to the inverter and connected devices:
- ન કરો exceed the inverter's rated power of 2000 Watts. Overloading can cause damage to the inverter and connected appliances.
- ન કરો leave the power inverter in the ON position while your vehicle's engine is off to prevent battery drain.
- Always disconnect the positive battery terminal before performing any wiring or maintenance on the inverter.
- Install the inverter in a cool, dry environment, away from direct sunlight, moisture, and flammable materials.
- Ensure proper ventilation around the inverter to prevent overheating. Do not block cooling fan vents.
- This inverter is designed for 12V DC input. Connecting to other voltage sources may cause severe damage.
3. સેટઅપ અને ઇન્સ્ટોલેશન
૩.૧ બેટરી સાથે કનેક્ટ કરવું
- Ensure the inverter's power switch is in the OFF position.
- Connect the red battery cable to the positive (+) terminal of your 12V battery.
- Connect the other end of the red battery cable to the positive (+) input terminal on the inverter.
- Connect the black battery cable to the negative (-) terminal of your 12V battery.
- Connect the other end of the black battery cable to the negative (-) input terminal on the inverter.
- ખાતરી કરો કે બધા જોડાણો ચુસ્ત અને સુરક્ષિત છે.
- Connect the included earth wire to the ground terminal on the inverter and to a suitable ground point.
નોંધ: For optimal performance and safety, use a 12V battery with a capacity of 400 Ah or above. Always use the provided cables or cables of equivalent gauge suitable for 2000W applications.
3.2 Remote Controller Installation
The remote controller allows for convenient monitoring and control of the inverter from a distance.
- Locate the RJ10 port on the inverter.
- Connect one end of the 15ft remote controller cable to the RJ10 port on the inverter.
- Connect the other end of the cable to the remote controller unit.
The inverter can also be turned on/off using the power switch directly on the unit if the remote controller is not connected or desired.

છબી 3.1: ઓવરview of inverter components including positive/negative terminals, GFCI outlets, USB ports, LCD display, and remote controller port.
4. ઓપરેશન
4.1 ઇન્વર્ટર પર પાવરિંગ
- After ensuring all connections are secure, switch the inverter's power button to the ON position.
- The LCD display on the inverter (or remote controller) will illuminate, showing input voltage, output wattage, and battery status.
૬.૨ એસી ઉપકરણોને જોડવા
The LEESKY 2000W inverter provides clean, stable pure sine wave electricity, suitable for sensitive electronics.
- Plug your AC devices into the two 110-120V AC GFCI outlets.
- For charging USB devices, use the two 2.4A USB ports.
- કુલ વોટની ખાતરી કરોtagબધા કનેક્ટેડ ઉપકરણોમાંથી e 2000W થી વધુ નથી.

Image 4.1: The inverter's LCD display provides real-time information, and the GFCI outlets offer enhanced safety.
4.3 LCD Display and Remote Control
The LCD display provides critical operational data:
- ઇનપુટ વોલ્યુમtage: Displays the current DC voltage બેટરીમાંથી.
- આઉટપુટ વોટtage: Shows the real-time power consumption of connected AC devices.
- બેટરી સ્થિતિ: બેટરી ચાર્જ સ્તર સૂચવે છે.
- પ્રોટેક્શન કોડ: Displays error codes if a protection mechanism is triggered.
- તાપમાન: Shows the internal temperature of the inverter.
The remote controller mirrors this information and allows for convenient power control. It also features a backlight switch for visibility in various lighting conditions.

Image 4.2: The remote control provides comprehensive monitoring and control, displaying input voltage, output wattage, battery status, and protection warnings.
5. Protection Features and Troubleshooting
The LEESKY 2000W inverter incorporates multiple protection mechanisms to ensure safe operation and prevent damage to the unit and connected devices. The LCD display will show warning symbols and protection codes when an issue occurs.
5.1 Built-in Protections:
- ઓવરલોડ પ્રોટેક્શન: Activates when output power exceeds 2000W-2200W. The inverter will shut down to prevent damage.
- અતિશય તાપમાન સંરક્ષણ: Engages if the internal temperature reaches approximately 149℉ (65℃). The intelligent cooling fan runs automatically when the temperature reaches 104℉ (40℃) or load power exceeds 40% of rated power.
- Low-input Voltage રક્ષણ: Triggers an alarm at 9.8V±0.5VDC and shuts down at 9.5V±0.5VDC to protect the battery from over-discharge.
- High-input Voltage રક્ષણ: Shuts down the inverter if input voltage exceeds 16V±0.5VDC.
- શોર્ટ-સર્કિટ પ્રોટેક્શન: Automatically protects against output short circuits.
- રિવર્સ પોલેરિટી પ્રોટેક્શન: Prevents damage from incorrect battery terminal connections.
- Input/Output Isolated Design: Enhances safety by electrically separating input and output circuits.

Image 5.1: The inverter's multi-protection system safeguards against common electrical faults.
5.2 Troubleshooting Common Issues:
| સમસ્યા | સંભવિત કારણ | ઉકેલ |
|---|---|---|
| ઇન્વર્ટર ચાલુ થતું નથી. | Loose battery connections, low battery voltage, inverter switch off. | Check battery connections, charge battery, ensure inverter switch is ON. |
| કોઈ એસી આઉટપુટ નથી. | Overload, short circuit, high/low input voltage, GFCI tripped. | Reduce load, check for short circuits, verify battery voltage, reset GFCI. |
| Inverter shuts down. | Overload, overheating, low/high input voltage. | Reduce load, allow inverter to cool, check battery voltage. |
| Fan runs constantly or loudly. | High internal temperature, heavy load. | Ensure adequate ventilation, reduce load. This is normal operation under certain conditions. |
6. જાળવણી
Regular maintenance ensures the longevity and reliable performance of your LEESKY inverter.
- સફાઈ: સમયાંતરે ઇન્વર્ટરના બાહ્ય ભાગને સૂકા, નરમ કપડાથી સાફ કરો. પ્રવાહી ક્લીનર્સ અથવા સોલવન્ટનો ઉપયોગ કરશો નહીં.
- વેન્ટિલેશન: Ensure the cooling vents are free from dust and debris. Blocked vents can lead to overheating.
- જોડાણો: Regularly check all battery and output connections to ensure they are tight and free from corrosion.
- સંગ્રહ: જો ઇન્વર્ટરને લાંબા સમય સુધી સ્ટોર કરી રહ્યા હોવ, તો તેને બેટરીથી ડિસ્કનેક્ટ કરો અને તેને ઠંડી, સૂકી જગ્યાએ સ્ટોર કરો.
7. સ્પષ્ટીકરણો
| લક્ષણ | સ્પષ્ટીકરણ |
|---|---|
| મોડલ | LEESKY 2000W Pure Sine Wave Inverter |
| રેટેડ પાવર | 2000W (સતત) |
| આઉટપુટ વેવફોર્મ | શુદ્ધ સાઇન વેવ |
| કુલ હાર્મોનિક વિકૃતિ (THD) | < 3% |
| ઇનપુટ વોલ્યુમtage | 12V ડીસી |
| આઉટપુટ વોલ્યુમtage | 110-120 VAC ± 10% |
| આઉટપુટ આવર્તન | 60Hz |
| નિષ્ક્રિય વર્તમાન | આશરે 1.7 Amps |
| કાર્યક્ષમતા | 90% સુધી |
| આઉટલેટ્સ | 2x GFCI Sockets |
| યુએસબી પોર્ટ્સ | 2x 2.4A USB |
| Remote Controller Cable Length | 15 ફૂટ |
| ઓવર-લોડ પ્રોટેક્શન | 2000W ~ 2200W |
| ઓવર-ટેમ્પરેચર પ્રોટેક્શન | Around 149°F (65°C) |
| કાર્યકારી તાપમાન | -22 ° F ~ 140 ° F (-30 ° C ~ 60 ° C) |
| ઓવર-વોલ્યુમtage શટડાઉન | 16V ± 0.5VDC |
| અંડર-વોલ્યુમtage એલાર્મ | 9.8V ± 0.5VDC |
| અંડર-વોલ્યુમtage શટડાઉન | 9.5V ± 0.5VDC |
| ઉત્પાદન પરિમાણો | 19.85 x 9.4 x 3.8 ઇંચ |
| વસ્તુનું વજન | 13.46 પાઉન્ડ |

Image 7.1: Physical dimensions and weight of the inverter, along with battery cable specifications.
8. વોરંટી અને સપોર્ટ
8.1 વોરંટી માહિતી
The LEESKY 2000W Pure Sine Wave Power Inverter comes with an 18-month maintenance period from the date of purchase. This warranty covers manufacturing defects and ensures product reliability. Please retain your proof of purchase for warranty claims.
8.2 ગ્રાહક સપોર્ટ
For technical assistance, troubleshooting, or warranty inquiries, please contact LEESKY customer support through the retailer where the product was purchased or refer to the official LEESKY webસંપર્ક વિગતો માટે સાઇટ.
PDF ફોર્મેટમાં વધારાની વપરાશકર્તા માર્ગદર્શિકા ડાઉનલોડ કરવા માટે ઉપલબ્ધ છે: વપરાશકર્તા માર્ગદર્શિકા (PDF) ડાઉનલોડ કરો