ઓટોલ LM160

AUTOOL LM160 સ્માર્ટ ડિજિટલ મેનીફોલ્ડ કીટ યુઝર મેન્યુઅલ

Model: LM160 | Brand: AUTOOL

1. ઉત્પાદન ઓવરview

The AUTOOL LM160 AC Manifold Gauge Set is a comprehensive digital tool designed for accurate measurement of temperature, pressure, and vacuum in refrigerant systems. It supports 95 types of refrigerants and offers various operational modes including evacuation, refrigeration, and pressure leak testing. This kit is suitable for a wide range of applications, from automotive to industrial refrigeration systems.

AUTOOL LM160 Digital Manifold Gauge Set with accessories

Image: The AUTOOL LM160 digital manifold gauge set, including the main unit, pipe clamp thermometers, refrigerant hoses, and a carrying case.

2. બોક્સમાં શું છે

Your AUTOOL LM160 package includes the following components:

Components of the AUTOOL LM160 kit

Image: All components of the AUTOOL LM160 kit laid out, including the digital gauge, hoses, temperature clamps, and carrying case.

3. સેટઅપ અને જોડાણો

Before operating the AUTOOL LM160, ensure all connections are secure and correct.

  1. Connect Temperature Probes: Insert the two pipe clamp thermometer probes into the designated ports on the top of the digital manifold unit. Securely attach the clamps to the refrigerant lines (e.g., suction and liquid lines) to measure pipe temperatures.
  2. Connect Refrigerant Hoses:
    • Connect the blue hose to the low-pressure (LP) side of the system and the blue port on the manifold.
    • Connect the red hose to the high-pressure (HP) side of the system and the red port on the manifold.
    • Connect the yellow hose to the service port (e.g., vacuum pump or refrigerant tank) and the central port on the manifold.
  3. પાવર ચાલુ: Press the power button to turn on the digital manifold gauge.

Video: This video demonstrates the connection of the clamp temperature probes and refrigerant lines to the AUTOOL LM160 digital manifold gauge, showing the initial setup process for AC system diagnostics.

4. ઓપરેટિંગ મોડ્સ

The AUTOOL LM160 offers three primary operating modes for comprehensive AC system analysis.

4.1. Vacuuming Mode

This mode is used to remove external gases and moisture from the refrigeration circuit, ensuring a clean system before refrigerant charging.

  1. Connect the yellow hose to a vacuum pump.
  2. Select "Evacuation" mode on the LM160.
  3. Open the low-pressure valve on the manifold.
  4. Activate the vacuum pump. The screen will display evacuation time, current pressure, water evaporation temperature, ambient temperature, and temperature difference.
  5. Monitor the vacuum level until the desired vacuum is achieved.
AUTOOL LM160 Vacuuming Mode screen

Image: The AUTOOL LM160 display showing the "Evacuation" mode interface, with real-time data for hold time, current pressure, water evaporation temperature, ambient temperature, and temperature difference.

4.2. Refrigeration Mode

In this mode, the gauge measures the pressure and temperature of the refrigeration system in real-time, allowing for accurate charging and performance assessment.

  1. Ensure the system is properly evacuated.
  2. Connect the yellow hose to the refrigerant tank.
  3. Select the desired refrigerant type from the built-in database (supports 95 refrigerants).
  4. Turn on the AC system of the vehicle/equipment.
  5. Open the LP and HP valves on the manifold to allow refrigerant flow.
  6. Monitor the LP (low pressure), HP (high pressure), Ev (evaporation temperature), Co (condensation temperature), T1 (evaporation temp. of measured pipe), T2 (condensation temp. of measured pipe), SH (superheating evaporation temp.), and SC (subcooling condensation temp.) readings on the display. The sight glass allows direct observation of refrigerant charge flow.
AUTOOL LM160 Refrigeration Mode screen

Image: The AUTOOL LM160 display showing the "Refrigeration" mode interface, providing real-time pressure and temperature data for various points in the AC system.

List of 95 supported refrigerants

Image: A comprehensive list of 95 refrigerants supported by the AUTOOL LM160, including common types like R134a, R22, R410A, and R1234yf.

4.3. Leakage Detection

This function helps determine if refrigerant is leaking by calculating the pressure difference over time.

  1. Ensure the system is charged to the appropriate pressure.
  2. Select "Pressure Leak Test" mode on the LM160.
  3. The device will record an initial pressure ("Start P").
  4. Monitor the "Current P" and "Delta P" (pressure difference) over a set period. A significant "Delta P" indicates a leak.
AUTOOL LM160 Pressure Leak Test screen

Image: The AUTOOL LM160 display showing the "Pressure Leak Test" mode interface, displaying start pressure, current pressure, and the calculated pressure difference over time.

૩. મુખ્ય લાક્ષણિકતાઓ અને કાર્યો

AUTOOL LM160 Multiple Units and Pressure Ranges

Image: The AUTOOL LM160 display showing the various units and pressure ranges supported for temperature, vacuum, and pressure measurements.

AUTOOL LM160 Design Features

છબી: ક્લોઝ-અપ views highlighting the 2.8-inch backlit display, silicone handles, foldable hook, and refrigerant visible window of the AUTOOL LM160.

AUTOOL LM160 Multi-language Support

Image: The AUTOOL LM160 display showing the language selection menu, indicating support for English, French, Italian, Spanish, German, Portuguese, Chinese, and Japanese.

6. સ્પષ્ટીકરણો

પરિમાણમૂલ્ય
ઉત્પાદન પરિમાણો15 x 13 x 5 ઇંચ
વસ્તુનું વજન9 પાઉન્ડ
મોડલ નંબરLM160
બ્રાન્ડAUTOOL
સામગ્રીGlass (for sight glass)
Pressure Measurement Unitspsi / kPa / MPa / bar / kg/cm²
Vacuum Measurement UnitsMicron / hPa / mbar / mTorr / Torr
તાપમાન એકમો° F / ° સે
Number of Supported Refrigerants95
ડિસ્પ્લેબેકલીટ ડિસ્પ્લે

7. જાળવણી

Proper maintenance ensures the longevity and accuracy of your AUTOOL LM160 Digital Manifold Kit.

8. મુશ્કેલીનિવારણ

If you encounter issues with your AUTOOL LM160, refer to the following common troubleshooting steps:

સમસ્યાસંભવિત કારણઉકેલ
યુનિટ પાવર ચાલુ કરતું નથીLow or dead batteries; power button issue.Replace batteries. Ensure power button is pressed firmly.
અચોક્કસ વાંચનLoose connections; sensor malfunction; need for calibration.Check all hose and probe connections. Ensure probes are clean and properly attached. Consider professional calibration if issues persist.
સ્ક્રીન સ્થિર અથવા પ્રતિભાવવિહીનસોફ્ટવેરમાં ખામી; બેટરી ઓછી.Restart the unit. Replace batteries. If problem persists, contact customer support.
"Delta P" in leak test is highRefrigerant leak in the system or connections.Inspect all connections, hoses, and system components for leaks. Use a leak detector if necessary.

For further assistance, please refer to the contact information in the Warranty and Support section.

9. વોરંટી અને સપોર્ટ

AUTOOL provides a three-year warranty for the LM160 AC Manifold Gauge Set. If the product has any defect, AUTOOL will provide a new replacement or solutions to ensure customer satisfaction without delay. Lifetime technical support is also provided.

For any needs or technical assistance, you are warmly welcomed to contact AUTOOL customer support. They aim to respond within 24 hours.

સંપર્ક માહિતી: Please refer to the contact details provided in your product packaging or visit the official AUTOOL webસૌથી અદ્યતન સપોર્ટ માહિતી માટે સાઇટ.

સંબંધિત દસ્તાવેજો - LM160

પ્રિview AUTOOL LM160 સ્માર્ટ ડિજિટલ મેનીફોલ્ડ કીટ યુઝર મેન્યુઅલ
This user manual provides comprehensive instructions for the AUTOOL LM160 Smart Digital Manifold Kit, covering safety rules, product description, technical specifications, operation, maintenance, and warranty information. It details the features and parameters of the device, including pressure and temperature measurements, vacuum capabilities, and compatibility with various refrigerants.
પ્રિview AUTOOL LM160 સ્માર્ટ ડિજિટલ મેનીફોલ્ડ કીટ યુઝર મેન્યુઅલ
AUTOOL LM160 સ્માર્ટ ડિજિટલ મેનીફોલ્ડ કિટ માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા, જે HVAC એપ્લિકેશનો માટે કામગીરી, તકનીકી વિશિષ્ટતાઓ, જાળવણી અને સલામતીને આવરી લે છે.
પ્રિview AUTOOL LM120+ ડિજિટલ મેનીફોલ્ડ ગેજ વપરાશકર્તા માર્ગદર્શિકા
Comprehensive user manual for the AUTOOL LM120+ Digital Manifold Gauge, detailing its features, specifications, safety precautions, operating instructions, and troubleshooting tips for refrigeration and HVAC systems.
પ્રિview AUTOOL LM110 ડિજિટલ મેનીફોલ્ડ ગેજ વપરાશકર્તા માર્ગદર્શિકા
AUTOOL LM110 ડિજિટલ મેનિફોલ્ડ ગેજ માટે વપરાશકર્તા માર્ગદર્શિકા, તેની સુવિધાઓ, કામગીરી, સ્પષ્ટીકરણો અને રેફ્રિજરેશન સિસ્ટમ જાળવણી માટે મુશ્કેલીનિવારણ પર વિગતવાર સૂચનાઓ પ્રદાન કરે છે.
પ્રિview AUTOOL LM150 Digital Manifold Pressure Tester User Manual - HVAC Refrigerant Tool
Comprehensive user manual for the AUTOOL LM150 Digital Manifold Pressure Tester. Covers product specifications, operating instructions for refrigerant filling, vacuum, and leak testing, common problems, glossary of terms, maintenance, warranty, and return policy for HVAC and refrigeration professionals.
પ્રિview AUTOOL LM120/LM120+ Digital Manifold Gauge User Manual
This user manual provides comprehensive guidance for the AUTOOL LM120/LM120+ Digital Manifold Gauge. It details product specifications, structure, function instructions for refrigerant filling, vacuum operation, and pressure leak testing. The manual also includes common problems, a glossary of terms, maintenance advice, warranty information, and return/exchange procedures. Essential for HVAC technicians and refrigeration professionals.