CMTOOL MD-12

CMTOOL Digital HVAC Manifold Gauge Set

મોડલ: MD-12

1. પરિચય

The CMTOOL Digital HVAC Manifold Gauge Set is designed for the installation, testing, and maintenance of refrigeration equipment such as air conditioners, refrigerators, and cold storage units. This manual provides essential information for safe and effective operation.

1.1 પેકેજ સામગ્રી

  • 1 x Digital Manifold Gauge Unit
  • 3 x Standard Test Hoses (1.5m)
  • 2 x તાપમાન Clamps
  • 1 x Portable Toolbox
  • 1 x વપરાશકર્તા માર્ગદર્શિકા
Contents of the CMTOOL Digital HVAC Manifold Gauge Set, including the main unit, hoses, temperature clamps, and carrying case.

Image: Components included in the CMTOOL Digital HVAC Manifold Gauge Set.

2. સલામતી માહિતી

સાધનસામગ્રીને ઇજા કે નુકસાન ન થાય તે માટે હંમેશા નીચેની સલામતી સાવચેતીઓનું પાલન કરો:

  • Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling refrigerants.
  • Ensure proper ventilation when working with refrigerants.
  • Do not exceed the maximum operating pressure of the hoses (600 PSI / 4.13 MPa). The limit pressure is 3000 PSI.
  • Verify that all connections are secure before applying pressure.
  • Avoid direct contact with refrigerants, as they can cause frostbite.
  • ઉપકરણને પાણી અને અતિશય તાપમાનથી દૂર રાખો.
  • Ensure the temperature sensor clips are properly connected for accurate readings.

3. ઉત્પાદન સુવિધાઓ

The CMTOOL Digital HVAC Manifold Gauge Set offers several advanced features for HVAC professionals:

  • Dual Pressure and Dual Temperature Measurement: Simultaneously measures two pressures (gauge pressure) and two temperatures.
  • Automatic Unit Conversion: Supports automatic conversion for pressure (kPa, MPa, Psi, Bar, InHg) and temperature (Celsius/Fahrenheit).
  • High-Precision Data Unit: Features a built-in 32-bit digital processing unit and high-precision data acquisition for stable and accurate readings.
  • Refrigerant Database: Contains a built-in database of 89 refrigerants, allowing for direct reading of pressure-evaporation temperature, superheat, and subcooling.
  • Vacuum Measurement: Tests the percentage of vacuum.
  • પ્રેશર લીક ટેસ્ટ: Calculates pressure difference over time to detect refrigerant leaks.
  • ટકાઉ બાંધકામ: Made with high-strength engineering plastics and flexible non-slip silicone for durability and comfortable handling.
  • Viewable Window and LCD Display: Allows direct observation of refrigerant charging status and features a 7.5CM×4CM LCD with backlight for clear data reading.
Diagram illustrating the key features of the digital manifold gauge set, including dual pressure and temperature test, superheat and subcooling calculation, pressure leakage test, vacuum pump operation, 32-bit high-precision data unit, support for 89 refrigerants, durable design, and LCD display.

છબી: ઓવરview of the digital manifold gauge set's key features.

List of 89 supported refrigerants, categorized by type, including R11, R134A, R22, R404A, R410A, and many others.

Image: Comprehensive list of 89 refrigerants supported by the device.

4. સેટઅપ

4.1 ઘટક ઓળખ

Diagram showing the components of the digital manifold gauge, including LCD display, function buttons, valves, and inlets, with dimensions.

Image: Labeled diagram of the digital manifold gauge components and dimensions.

  1. Clamp-on Temperature Probe Socket
  2. એલસીડી ડિસ્પ્લે
  3. ફંક્શન બટન
  4. રન/સ્ટોપ બટન
  5. R+/R- Refrigerant Type Selection Buttons
  6. યુનિટ બટન
  7. ઝીરો બટન
  8. બેકલાઇટ બટન
  9. ° સી / ° એફ બટન
  10. પાવર બટન
  11. નીચા દબાણ વાલ્વ
  12. રેફ્રિજન્ટ અવલોકન વિન્ડો
  13. 1/4 inch Low Pressure Inlet
  14. ઉચ્ચ દબાણ વાલ્વ
  15. પ્રેશર રીલીઝ વાલ્વ
  16. 1/4 inch High Pressure Inlet
  17. રેફ્રિજરન્ટ ઇનલેટ / વેક્યુમ પંપ ઇનલેટ

4.2 Connecting Hoses and Clamps

  1. Connect the appropriate test hoses to the low pressure inlet (14), high pressure inlet (17), and refrigerant/vacuum pump inlet (18) on the manifold gauge.
  2. Attach the other ends of the hoses to the service ports of the HVAC system.
  3. Plug the temperature clamps into the Clamp-on Temperature Probe Sockets (1).
  4. Securely attach the temperature clamps to the refrigerant pipes to measure pipe surface temperature.

5. ઓપરેટિંગ સૂચનાઓ

૬.૧ પાવર ચાલુ/બંધ અને બેકલાઇટ

  • Press the Power Button (11) to turn the device on or off.
  • Press the Backlit Button (9) to activate or deactivate the LCD backlight for improved visibility in low-light conditions.

5.2 Selecting Refrigerant Type

  • Use the R+/R- Refrigerant Type Selection Buttons (6) to scroll through the built-in refrigerant database and select the refrigerant being used (e.g., R134A, R410A).

5.3 દબાણ અને તાપમાન માપન

The device displays dual pressure and dual temperature readings simultaneously.

  • Ensure hoses and temperature clamps યોગ્ય રીતે જોડાયેલા છે.
  • The LCD Display (2) will show T1 and T2 temperatures, along with corresponding pressures.
  • Press the Unit Button (7) to cycle through different pressure units (kPa, MPa, Psi, Bar, InHg).
  • Press the °C/°F Button (10) to switch between Celsius and Fahrenheit temperature units.
Close-up of the digital manifold gauge display showing dual temperature and pressure readings in kPa, with an overlay explaining the pressure test units.

Image: Dual pressure and temperature measurement display.

5.4 Superheat and Subcooling Calculation

The gauge automatically calculates superheat and subcooling based on the selected refrigerant and measured values.

  • After selecting the refrigerant, the display will show the calculated superheat (SH) and subcooling (SC) values.
Digital manifold gauge display showing refrigerant type, pressure, temperature, and calculated superheat and subcooling values.

Image: Display showing refrigerant data, superheat, and subcooling.

5.5 પ્રેશર લીક ટેસ્ટ

To perform a pressure leak test:

  1. Connect the gauge to the system and pressurize it.
  2. Press the Function Button (3) to enter the leak test mode.
  3. The gauge will record the initial pressure and continuously monitor for changes.
  4. The display will show the leak time (HH:MM) and the pressure difference (ΔP) between the initial and instantaneous pressure values.
Digital manifold gauge display showing the pressure leakage test interface, with leak time, initial pressure value, and instantaneous pressure value highlighted.

Image: Pressure leak test display.

5.6 વેક્યુમ માપન

The device can measure the percentage of vacuum.

  • Connect the gauge to the system and initiate the vacuum process.
  • The display will show the vacuum percentage.
A technician using the CMTOOL digital manifold gauge to service an automotive air conditioning system.

Image: Technician performing HVAC system service with the gauge.

6. જાળવણી

6.1 સફાઈ

  • Wipe the gauge unit with a soft, damp કાપડ ઘર્ષક ક્લીનર્સ અથવા સોલવન્ટનો ઉપયોગ કરશો નહીં.
  • Ensure the temperature clamps and hoses are clean and free of debris after each use.

6.2 સંગ્રહ

  • Store the manifold gauge set in its portable toolbox to protect it from dust and physical damage.
  • Keep the device in a dry environment, away from direct sunlight and extreme temperatures.

7. મુશ્કેલીનિવારણ

૬.૨ અચોક્કસ તાપમાન વાંચન

  • મુદ્દો: Temperature readings appear incorrect or unstable.
  • ઉકેલ: Ensure the temperature sensor clips are properly connected to the probe sockets and securely attached to the refrigerant pipes. A poor connection can lead to inaccurate values.

7.2 No Display or Device Not Powering On

  • મુદ્દો: The LCD display is blank or the device does not turn on.
  • ઉકેલ: Check the battery compartment for proper battery installation and charge level. Replace batteries if necessary.

7.3 Pressure Readings are Unstable or Incorrect

  • મુદ્દો: Pressure readings fluctuate excessively or seem inaccurate.
  • ઉકેલ: Verify all hose connections are tight and free of leaks. Ensure the correct refrigerant type is selected in the device settings.

8. સ્પષ્ટીકરણો

લક્ષણવિગત
મોડલ નંબરMD-12
ઉત્પાદન પરિમાણો13.98 x 12.71 x 4.61 ઇંચ
વસ્તુનું વજન6.6 પાઉન્ડ
સામગ્રીHigh-strength engineering plastics, flexible non-slip silicone
સપોર્ટેડ રેફ્રિજન્ટ89 types (e.g., R11, R12, R22, R134A, R404A, R410A, 1234YF)
નળી ઓપરેટિંગ દબાણMax 600 PSI (4.13 MPa)
Hose Limit Pressure3000 PSI
ડિસ્પ્લે7.5CM×4CM LCD with backlight
ડેટા પ્રોસેસિંગ યુનિટ32-bit digital

9. વોરંટી અને સપોર્ટ

CMTOOL products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official CMTOOL webસાઇટ. વોરંટી દાવાઓ માટે કૃપા કરીને તમારી ખરીદીનો પુરાવો રાખો.

સંબંધિત દસ્તાવેજો - MD-12

પ્રિview ડિજિટલ મેનીફોલ્ડ પ્રેશર ટેસ્ટર યુઝર મેન્યુઅલ - CMTOOL
CMTOOL ડિજિટલ મેનીફોલ્ડ પ્રેશર ટેસ્ટર માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા, જે HVAC સિસ્ટમ્સ માટે ઇન્સ્ટોલેશન, સંચાલન, સલામતી અને મુશ્કેલીનિવારણને આવરી લે છે. વિગતવાર સ્પષ્ટીકરણો અને રેફ્રિજન્ટ સુસંગતતા શામેલ છે.
પ્રિview CMTOOL ડિજિટલ વેક્યુમ ગેજ વપરાશકર્તા માર્ગદર્શિકા
CMTOOL ડિજિટલ વેક્યુમ ગેજ માટે વપરાશકર્તા માર્ગદર્શિકા, સલામતી, તકનીકી વિશિષ્ટતાઓ, સાધનનું વર્ણન, ઓપરેશન મોડ્સ, જાળવણી અને વોરંટી માહિતીને આવરી લે છે.
પ્રિview ઓટોમોટિવ સર્કિટ ટેસ્ટર વપરાશકર્તા માર્ગદર્શિકા
વાહનોમાં પોલેરિટી ટેસ્ટિંગ, કન્ટીન્યુટી ટેસ્ટિંગ અને કમ્પોનન્ટ ટેસ્ટિંગ માટે ઓટોમોટિવ સર્કિટ ટેસ્ટરનો ઉપયોગ કરવા માટેની માર્ગદર્શિકા. તેમાં સ્પષ્ટીકરણો અને સલામતી નોંધો શામેલ છે.
પ્રિview CMTOOL ફ્યુઅલ સિસ્ટમ ક્લીનર યુઝર મેન્યુઅલ - ઓટોમોટિવ મેન્ટેનન્સ ગાઇડ
CMTOOL ફ્યુઅલ સિસ્ટમ ક્લીનર (BT360) માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા. વિગતવાર સૂચનાઓ અને સાવચેતીઓ સાથે તમારા વાહનની ફ્યુઅલ સિસ્ટમ, ઇન્ટેક મેનીફોલ્ડ અને થ્રોટલ બોડીને સુરક્ષિત અને અસરકારક રીતે કેવી રીતે સાફ કરવી તે શીખો.
પ્રિview CMTOOL Air Quality Detector User Manual
User manual for the CMTOOL Air Quality Detector, providing instructions on operation, instrument introduction, display content, power supply, and warranty information.
પ્રિview CMTOOL આર્ટિક્યુલેટિંગ વિડીયો બોરેસ્કોપ યુઝર મેન્યુઅલ