ACiQ ACiQ-24-AC / ACIQ-24-ACL

ACiQ 16.5 SEER2 Inverter Air Conditioner & Evaporator Coil System User Manual

Model: ACiQ-24-AC / ACIQ-24-ACL | Brand: ACiQ

1. પરિચય

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ High Efficiency 16.5 SEER2 24,000 Cooling BTU Inverter Air Conditioner and Multi-Positional Cased Evaporator Coil System. Please read this manual thoroughly before installation or operation and keep it for future reference.

The ACiQ system is designed to provide optimal cooling performance with advanced inverter technology, ensuring consistent temperature control and energy efficiency. This system includes an outdoor inverter unit, a multi-positional cased evaporator coil, and a smart thermostat for convenient control.

2. મહત્વપૂર્ણ સલામતી માહિતી

ચેતવણી: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Refer to this manual. For assistance or additional information, consult a qualified installer or service agency.

3. પેકેજ સામગ્રી

પ્રાપ્તિ સમયે ખાતરી કરો કે બધા ઘટકો હાજર છે અને નુકસાન વિનાના છે:

ACiQ Inverter Air Conditioner and Evaporator Coil System with Smart Thermostat

આકૃતિ 3.1: ઓવરview of the ACiQ Inverter Air Conditioner and Evaporator Coil System, including the outdoor unit, cased evaporator coil, and smart thermostat.

4. સેટઅપ અને ઇન્સ્ટોલેશન

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician to ensure proper function, safety, and warranty validity.

4.1 Unit Placement and Dimensions

Ensure adequate clearance around both the outdoor and indoor units for proper airflow and maintenance access. Refer to the following dimensions for planning:

Diagram showing measurements of ACiQ outdoor unit and evaporator coil

Figure 4.1: Detailed measurements for the ACiQ outdoor unit and evaporator coil, indicating dimensions for installation planning.

4.2 Evaporator Coil Installation

The cased multi-positional evaporator coil is designed for versatile installation in various configurations. It is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator coil with specifications for air flow, pressure, and dimensions

Figure 4.2: Specifications for the ACiQ evaporator coil, including air flow, pressure, and physical dimensions.

4.3 વિદ્યુત જોડાણો

The system requires a 208-230 voltage, 1-Phase, 60Hz electrical supply. All electrical wiring must comply with local and national electrical codes. Ensure proper circuit breaker sizing and wiring gauge for the unit's power requirements.

4.4 રેફ્રિજન્ટ પાઇપિંગ

This system uses R 410A refrigerant. Proper evacuation and charging procedures are critical for system performance and longevity. This process must be performed by a licensed HVAC technician.

5. ઓપરેટિંગ સૂચનાઓ

Your ACiQ system is controlled by the included Cielo Smart Thermostat, designed for user convenience and energy efficiency.

5.1 Cielo Smart Thermostat Overview

The Cielo Smart Thermostat allows you to manage your cooling and heating settings efficiently. It ensures your system runs only when needed, helping to reduce energy consumption without compromising comfort.

Cielo Smart Thermostat and its mobile app interface

Figure 5.1: The Cielo Smart Thermostat, illustrating its sleek design and integration with a mobile application for remote control.

5.2 Thermostat Features and Controls

The thermostat offers various features for precise climate control and smart home integration:

Diagram of Cielo Smart Thermostat features including mode, humidity, set points, and smart home integrations

Figure 5.2: An illustrative diagram detailing the various features and control points of the Cielo Smart Thermostat, including its compatibility with popular smart home platforms.

6. જાળવણી

Regular maintenance ensures the longevity and efficiency of your ACiQ system. Always disconnect power to the unit before performing any maintenance.

6.1 Air Filter Replacement/Cleaning

Check and clean or replace the air filter in your furnace or air handler every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow and reduces efficiency.

6.2 Outdoor Unit Coil Cleaning

Periodically inspect the outdoor unit's condenser coil for dirt, leaves, and debris. Gently clean the coil with a soft brush or hose. Avoid bending the fins. Ensure the area around the outdoor unit is clear of obstructions.

Close-up of the ACiQ outdoor unit's fan and coil

આકૃતિ ૩: ક્લોઝ-અપ view of the ACiQ outdoor unit, highlighting the fan and condenser coil, which require periodic cleaning for optimal performance.

૭.૨ વ્યાવસાયિક સેવા

It is recommended to have a qualified HVAC technician perform annual maintenance on your system. This includes checking refrigerant levels, electrical connections, and overall system performance.

7. મુશ્કેલીનિવારણ

ગ્રાહક સપોર્ટનો સંપર્ક કરતા પહેલા, ફરીથીview નીચેના સામાન્ય મુદ્દાઓ અને તેમના ઉકેલો:

સમસ્યાસંભવિત કારણઉકેલ
System not cooling/heatingThermostat settings incorrect, dirty air filter, tripped circuit breaker, outdoor unit obstructed.Check thermostat mode and temperature settings. Clean/replace air filter. Reset circuit breaker. Clear obstructions around outdoor unit.
નબળો હવા પ્રવાહDirty air filter, blocked return air vents, duct leaks.Clean/replace air filter. Ensure vents are open and unobstructed. Inspect ducts for leaks (professional service recommended).
અસામાન્ય અવાજોLoose parts, fan motor issues, refrigerant issues.Turn off unit and inspect for loose panels or debris. If noise persists, contact a qualified technician.
System cycles on and off frequentlyOversized unit, low refrigerant, dirty coils.Ensure proper sizing during installation. Check for refrigerant leaks and clean coils. Contact a technician for diagnosis.
Leak detection alertરેફ્રિજન્ટ લીક.The system is equipped with leak detection. If an alert occurs, immediately contact a qualified HVAC technician for inspection and repair.

8. સ્પષ્ટીકરણો

Key technical specifications for the ACiQ 16.5 SEER2 24,000 BTU Inverter Air Conditioner and Evaporator Coil System:

લક્ષણવિગત
બ્રાન્ડACiQ
મોડેલનું નામACiQ-24-AC / ACIQ-24-ACL
ઠંડક ક્ષમતા24,000 BTU/h (2 Tons)
SEER2 રેટિંગ16.5 સુધી
પાવર સ્ત્રોતકોર્ડેડ ઇલેક્ટ્રિક
ભાગtage208-230V, 1-Phase, 60Hz
રેફ્રિજન્ટ પ્રકારઆર ૪૧૦એ
આઉટડોર યુનિટના પરિમાણો (W x D x H)૧૨.૨" x ૧૪" x ૫૭.૨"
Evaporator Coil Dimensions (W x D x H)૧૨.૨" x ૧૪" x ૫૭.૨"
નિયંત્રણ પદ્ધતિRemote Control (Cielo Smart Thermostat)
AHRI Certification and EnergyGuide label for ACiQ system

Figure 8.1: AHRI Certification and EnergyGuide label, confirming the system's performance ratings and energy efficiency.

9. વોરંટી અને સપોર્ટ

9.1 વોરંટી શરતો

The ACiQ system comes with a 10-વર્ષના ભાગોની વોરંટી when installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

For detailed warranty terms and conditions, please refer to the warranty documentation included with your product or visit the official ACiQ webસાઇટ

Warehouse showing packaged AC units ready for shipment

Figure 9.1: Expert packaging of ACiQ units in a warehouse, ensuring product integrity during transit.

Well-kept warehouse interior with organized product shelving

આકૃતિ 9.2: આંતરિક view of a well-maintained ACiQ warehouse, demonstrating careful handling and storage of products.

9.2 ગ્રાહક સપોર્ટ

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact ACiQ customer support. Contact information can typically be found on the manufacturer's webસાઇટ પર અથવા ઉત્પાદન પેકેજિંગ પર.

When contacting support, please have your model number (ACiQ-24-AC / ACIQ-24-ACL) and purchase date readily available.

10. વધારાના સંસાધનો

For further information, product updates, or to explore other ACiQ products, please visit the official ACiQ webસાઇટ:

Visit the ACiQ Store on Amazon

સંબંધિત દસ્તાવેજો - ACiQ-24-AC / ACIQ-24-ACL

પ્રિview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
પ્રિview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures. Includes model details and important notes for proper setup.
પ્રિview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
પ્રિview ACiQ ડક્ટેડ એર હેન્ડલર ઇન્સ્ટોલેશન મેન્યુઅલ (12K-60K BTU/h)
ACiQ નું આ ઇન્સ્ટોલેશન મેન્યુઅલ ડક્ટેડ એર હેન્ડલર યુનિટ્સ, 12K થી 60K BTU/h મોડેલોના સલામત અને યોગ્ય ઇન્સ્ટોલેશન માટે વિગતવાર સૂચનાઓ પ્રદાન કરે છે. તે શ્રેષ્ઠ કામગીરી અને સિસ્ટમની ટકાઉપણું સુનિશ્ચિત કરવા માટે આવશ્યક સલામતી માર્ગદર્શિકા, યુનિટ પ્લેસમેન્ટ, રેફ્રિજન્ટ પાઇપિંગ, ઇલેક્ટ્રિકલ વાયરિંગ, સ્પષ્ટીકરણો અને ઓપરેશનલ પરીક્ષણને આવરી લે છે.
પ્રિview ACiQ એક્સ્ટ્રીમ+ ડક્ટેડ એર હેન્ડલર માલિકનું મેન્યુઅલ
ACiQ એક્સ્ટ્રીમ+ ડક્ટેડ એર હેન્ડલર (18K-60K) માટે વ્યાપક માલિકનું માર્ગદર્શિકા, જેમાં સલામતીની સાવચેતીઓ, ભાગો, જાળવણી અને મુશ્કેલીનિવારણનો સમાવેશ થાય છે.
પ્રિview ACiQ ડક્ટેડ એર હેન્ડલર ઇન્સ્ટોલેશન મેન્યુઅલ
ACiQ ડક્ટેડ એર હેન્ડલર યુનિટ્સ (12K-60K BTU/h) માટે વ્યાપક ઇન્સ્ટોલેશન મેન્યુઅલ. ACiQ-12-AHD થી ACiQ-60-AHD મોડેલ્સ માટે સલામતી, યુનિટ ઇન્સ્ટોલેશન, વાયરિંગ, રેફ્રિજન્ટ પાઇપિંગ અને પરીક્ષણ પ્રક્રિયાઓને આવરી લે છે.