AIDA B0DM4SGNBQ

AIDA Single Pole Motion Sensor Light Switch User Manual

Model: B0DM4SGNBQ

બ્રાન્ડ: AIDA

પરિચય

This manual provides detailed instructions for the installation, operation, and maintenance of your AIDA Single Pole Motion Sensor Light Switch. This device is designed to enhance convenience and energy efficiency by automatically controlling lighting based on occupancy. Please read this manual thoroughly before installation and use to ensure proper function and safety.

AIDA Single Pole Motion Sensor Light Switch and its packaging

Image: The AIDA Single Pole Motion Sensor Light Switch shown alongside its product packaging, highlighting its design and key features.

મહત્વપૂર્ણ સલામતી માહિતી

WARNING: RISK OF ELECTRIC SHOCK. Improper installation can be dangerous or illegal. Always consult a qualified electrician if you are unsure about any part of the installation process.

  • પાવર બંધ કરો: Always disconnect power at the circuit breaker or fuse box before installing or servicing the switch.
  • તટસ્થ વાયર જરૂરી: This device requires a neutral wire for proper operation. If your electrical box does not have a neutral wire, this switch is not compatible.
  • Single Pole Only: This switch is designed for single-pole control only and is not suitable for 3-way or multiple-way circuits.
  • UL/CUL Certified: The switch is UL and CUL listed, ensuring compliance with safety standards.
  • સંચાલન ભાગtage: Ensure your electrical system operates at 120 Volts (AC).

પેકેજ સામગ્રી

ઇન્સ્ટોલેશન શરૂ કરતા પહેલા ખાતરી કરો કે બધા ઘટકો હાજર છે:

  • AIDA Single Pole Occupancy Motion Sensor Light Switch
  • સ્ક્રુલેસ વોલ પ્લેટ
  • Wire Nuts (Terminal caps)
  • માઉન્ટિંગ સ્ક્રૂ
  • સૂચના માર્ગદર્શિકા (આ દસ્તાવેજ)

ઉત્પાદન સ્પષ્ટીકરણો

લક્ષણ વિગત
ઇનપુટ રેટિંગ ૧૮૦/૨૪૦વી~૫૦/૬૦હર્ટ્ઝ
Applicable Load Types 200W LED/CFL, 500W MLV, 500W INC/HAL, 5A Ballast (120V), 1/6HP Fan (4.4A 120V)
સ્વિચ પ્રકાર એક ધ્રુવ
વાયર ગેજ #14 - #12 AWG
વાયરિંગનો પ્રકાર ટર્મિનલ કેપ
ઓપરેટિંગ તાપમાન 32°F થી 104°F (0°C થી 40°C)
ઉત્પાદન કદ 4.17"x1.73"x1.77" (106x44x45mm)
સામગ્રી Copper, Brass (Contact Material)
નિયંત્રણ પદ્ધતિ Sensor, Touch
ઉત્પાદનના પરિમાણો અને સ્પષ્ટીકરણોનું કોષ્ટક

Image: A visual representation of the product dimensions and a detailed table of specifications for the AIDA motion sensor switch.

Universal compatibility chart for AIDA motion sensor switch

Image: A chart illustrating the universal compatibility of the AIDA motion sensor switch with various load types including LED/CFL, MLV, INV/HAL, Ballast, and Fan.

સેટઅપ અને ઇન્સ્ટોલેશન

તમે પ્રારંભ કરો તે પહેલાં:

  1. પાવર બંધ કરો: Locate your circuit breaker panel and turn off the power to the switch box you will be working on. Verify power is off using a voltage પરીક્ષક.
  2. વાયર ઓળખો: Carefully remove the existing wall plate and switch. Identify the following wires:
    • Line Wire (Black): સર્કિટ બ્રેકરમાંથી પાવર વહન કરે છે.
    • Load Wire (Black): Carries power to the light fixture.
    • તટસ્થ વાયર (સફેદ): Required for this switch.
    • ગ્રાઉન્ડ વાયર (લીલો અથવા એકદમ કોપર): For safety.
  3. Confirm Neutral Wire: This switch requires a neutral wire. If you do not have a neutral wire (typically white) in your electrical box, this switch is not compatible.

વાયરિંગ સૂચનાઓ:

Follow the wiring diagram carefully. Use the provided wire nuts to secure connections.

Wiring diagram for AIDA motion sensor light switch

Image: A detailed wiring diagram showing connections for the AIDA motion sensor light switch, including Line, Load, Neutral, and Ground wires. It explicitly states that a neutral wire is required and the switch is not suitable for 3-way or multiple-way circuits.

  • કનેક્ટ કરો લીલો wire from the switch to your house's ગ્રાઉન્ડ વાયર
  • કનેક્ટ કરો સફેદ wire from the switch to your house's તટસ્થ વાયર
  • કનેક્ટ કરો કાળો wire from the switch to your house's લાઇન (ગરમ તાર.
  • કનેક્ટ કરો લાલ wire from the switch to your house's લોડ wire (to the light fixture).

Important: Ensure all connections are secure and insulated with wire nuts. This switch is for single-pole applications only. Do not use in 3-way or multi-way circuits.

સ્વીચ માઉન્ટ કરી રહ્યું છે:

  1. Carefully fold the wires and push the switch into the electrical box.
  2. Secure the switch to the electrical box using the provided screws.
  3. Attach the screwless wall plate.
  4. સર્કિટ બ્રેકર પર પાવર પુનઃસ્થાપિત કરો.
Dimensions of the AIDA motion sensor light switch and wall plate

Image: A diagram showing the precise dimensions of the AIDA motion sensor light switch, its mounting bracket, and the screwless wall plate for easy installation.

Operating Instructions and Customization

The AIDA motion sensor switch offers various modes and adjustable settings to suit your needs.

ઓપરેશન મોડ્સ:

  • Occupancy Mode (Auto-On/Auto-Off): Lights automatically turn ON when motion is detected and OFF after a set delay when no motion is detected. Ideal for high-traffic areas like bathrooms, laundry rooms, and kitchens.
  • Vacancy Mode (Manual-On/Auto-Off): Lights must be manually turned ON, but will automatically turn OFF after a set delay when no motion is detected. Suitable for bedrooms or TV rooms where you prefer manual control for turning on lights.

એડજસ્ટેબલ સેટિંગ્સ:

The switch features internal dip switches for customizing settings. Carefully remove the faceplate to access these controls.

Adjustable settings for AIDA motion sensor switch

છબી: ક્લોઝ-અપ view of the AIDA motion sensor switch's internal settings, showing dip switches for Adjustable Light Level (Timeout), PIR Sensitivity, and Ambient Light Sensor Mode.

  • Adjustable Light Level (Timeout): This setting determines how long the light stays on after the last detected motion. Options typically include 30 seconds, 1 minute, 5 minutes, 15 minutes, or 30 minutes. Refer to the switch's internal labels for specific settings.
  • પીર સંવેદનશીલતા: Adjusts the sensitivity of the Passive Infrared (PIR) sensor to detect motion. Settings range from Low (L) to High (H). A higher sensitivity detects smaller movements or movements at a greater distance.
  • Ambient Light Sensor Mode: Controls how the switch reacts to ambient light.
    • નીચું/ઉચ્ચ: The switch will only turn on lights if the ambient light level is below a certain threshold (e.g., only turn on at night).
    • બંધ: The ambient light sensor is disabled, and the switch will turn on lights regardless of ambient light.
    • કસ્ટમ: Allows for more specific ambient light level adjustments.

Note: After adjusting any internal settings, reattach the faceplate securely.

વિગતવાર view of AIDA motion sensor switch internal settings

છબી: વિગતવાર view of the AIDA motion sensor switch with its cover removed, showing the dip switches for adjusting timeout, PIR sensitivity, and ambient light sensor mode.

જાળવણી

The AIDA Motion Sensor Light Switch is designed for long-lasting, maintenance-free operation. To ensure optimal performance:

  • સફાઈ: Periodically wipe the switch and wall plate with a soft, damp કાપડ. ઘર્ષક ક્લીનર્સ અથવા સોલવન્ટ્સનો ઉપયોગ કરશો નહીં, કારણ કે આ ફિનિશ અથવા આંતરિક ઘટકોને નુકસાન પહોંચાડી શકે છે.
  • અવરોધ: Ensure the sensor lens is not obstructed by furniture, decorations, or other objects, as this can impair motion detection.
  • કોઈ વપરાશકર્તા સેવાયોગ્ય ભાગો નથી: There are no user-serviceable parts inside the switch. Do not attempt to open or repair the unit beyond adjusting the dip switches.

મુશ્કેલીનિવારણ

સમસ્યા સંભવિત કારણ ઉકેલ
Light does not turn ON with motion.
  • પાવર બંધ છે.
  • ખોટી વાયરિંગ.
  • PIR sensitivity set too low.
  • Ambient light sensor preventing activation.
  • Obstruction blocking sensor.
  • સર્કિટ બ્રેકર તપાસો.
  • Verify wiring according to diagram (ensure neutral wire is connected).
  • Increase PIR sensitivity.
  • Adjust Ambient Light Sensor Mode or set to "Off" for testing.
  • સેન્સરમાંથી કોઈપણ અવરોધો દૂર કરો view.
Light stays ON constantly.
  • સતત ગતિ મળી.
  • Switch set to Manual ON mode (if applicable).
  • ખામીયુક્ત સ્વીચ.
  • Ensure no continuous motion in the detection area.
  • Check operating mode settings.
  • જો સમસ્યા ચાલુ રહે, તો ગ્રાહક સપોર્ટનો સંપર્ક કરો.
Light turns OFF too quickly or too slowly.
  • Timeout setting needs adjustment.
  • Adjust the "Adjustable Light Level (Timeout)" setting using the internal dip switches.
Switch makes a clicking noise.
  • Normal operation of the internal relay.
  • This is a normal operational sound and does not indicate a fault.

વોરંટી અને ગ્રાહક આધાર

AIDA products are manufactured to high-quality standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty card included with your purchase or visit the official AIDA webસાઇટ

If you encounter any issues or have questions regarding your AIDA Single Pole Motion Sensor Light Switch, please contact our customer support team:

  • Webસાઇટ: Visit the AIDA Store on Amazon (સામાન્ય ઉત્પાદન માહિતી માટે)
  • ઈમેલ: ઉત્પાદન પેકેજિંગ અથવા સત્તાવારનો સંદર્ભ લો webસંપર્ક ઇમેઇલ માટે સાઇટ.
  • ફોન: ઉત્પાદન પેકેજિંગ અથવા સત્તાવારનો સંદર્ભ લો website for contact phone number.

Please have your model number (B0DM4SGNBQ) and purchase date ready when contacting support.

સંબંધિત દસ્તાવેજો - B0DM4SGNBQ

પ્રિview AIDA HD-NDI-200 Full-HD NDI|HX2 POV Camera User Manual
User manual for the AIDA HD-NDI-200 Full-HD NDI|HX2 POV Camera. Covers safety, packing, highlights, technical specifications, OSD and web interface settings, VISCA and NDI protocols, and warranty information.
પ્રિview AIDA HD-100 HD HDMI POV Camera Operation Guide
This operation guide provides detailed instructions for the AIDA HD-100 HD HDMI POV Camera, covering features, OSD menu settings, image controls, and specifications.
પ્રિview Aida Wireless Doorbell Installation and Operation Guide
Comprehensive guide to installing, pairing, and operating the Aida Wireless Doorbell. Features include 32 melodies, 150m range, 5 volume levels, and a waterproof bell push.
પ્રિview AIDA GEN3G-200: 3G-SDI/HDMI FULL HD Gen-lock Camera Operation Guide
Comprehensive operation guide for the AIDA GEN3G-200, a 3G-SDI/HDMI FULL HD Gen-lock camera. Covers features, menu operations, specifications, and safety precautions.
પ્રિview AIDA ફુલ-એચડી ઓપ્ટિકલ ઝૂમ PTZ કેમેરા મેન્યુઅલ - PTZ-X12-IP, PTZ-NDI-X12, PTZ-X20-IP, PTZ-NDI-X20
AIDA ના ફુલ-એચડી ઓપ્ટિકલ ઝૂમ PTZ કેમેરા (PTZ-X12-IP, PTZ-NDI-X12, PTZ-X20-IP, PTZ-NDI-X20) માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા. સલામતી, સેટઅપ, ઉત્પાદન હાઇલાઇટ્સ, સ્પષ્ટીકરણો, ઇન્ટરફેસ, રિમોટ કંટ્રોલ, OSD મેનુ, web સેટિંગ્સ, VISCA પ્રોટોકોલ (IP અને RS-232), UVC નિયંત્રણ અને વોરંટી માહિતી.
પ્રિview Telkonet Aida Thermostat: Installation, Operation, and Maintenance Guide
This guide provides detailed instructions for the installation, operation, and maintenance of the Telkonet Aida smart thermostat. It covers product features, installation procedures for high and low voltage systems, wiring diagrams, user interface explanations, and compliance information.