NJTY T3

NJTY T3 Multimeter Instruction Manual

મોડલ: T3

પરિચય

This manual provides detailed instructions for the safe and effective use of the NJTY T3 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference. The NJTY T3 is a rechargeable, auto-ranging digital multimeter designed for accurate measurements of AC/DC voltage, resistance, and features Non-Contact Voltage (NCV) detection and live wire testing.

NJTY T3 Multimeter with probes and charging cable

Image: The NJTY T3 Digital Multimeter, showing its main unit, red and black test probes, and a USB-C charging cable connected.

સલામતી માહિતી

Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the device.

પેકેજ સામગ્રી

ખાતરી કરો કે બધી વસ્તુઓ પેકેજમાં હાજર છે:

સેટઅપ

૪.૩. પ્રારંભિક ચાર્જિંગ

The NJTY T3 Multimeter features a built-in rechargeable Lithium Ion battery. Before first use, or if the low battery indicator is displayed, charge the device using the provided Type-C charging cable.

  1. Connect the Type-C end of the charging cable to the multimeter's charging port.
  2. Connect the USB-A end of the charging cable to a standard USB power adapter (not included) or a computer's USB port.
  3. The charging indicator on the multimeter will illuminate during charging and turn off when fully charged.
NJTY T3 Multimeter connected to a laptop via Type-C charging cable

Image: The NJTY T3 Multimeter being charged via its Type-C port, connected to a laptop.

2. ટેસ્ટ લીડ્સને કનેક્ટ કરવું

Insert the red test lead into the "VΩ" input jack and the black test lead into the "COM" input jack. Ensure they are securely seated.

ઓપરેટિંગ સૂચનાઓ

The NJTY T3 Multimeter features an auto-ranging function, simplifying operation by automatically detecting the measurement type and range.

1. પાવર ચાલુ/બંધ

Press and hold the power button to turn the multimeter on or off. The device will automatically shut off after approximately 15 minutes of inactivity to conserve battery life.

2. Automatic Measurement (Auto-Ranging)

In auto-ranging mode, the multimeter will automatically identify and measure AC voltage, DC વોલ્યુમtage, or resistance when the test leads are applied to a circuit. The display will show the measurement type (AC, DC, Ω) and the value.

NJTY T3 Multimeter displaying 'Auto function scan' with icons for various measurement modes

Image: The NJTY T3 Multimeter screen showing "Auto function scan" and icons representing AC/DC voltage, resistance, continuity, NCV, and flashlight functions.

3. AC/DC વોલ્યુમtage માપન

  1. Ensure the multimeter is powered on.
  2. ટેસ્ટ લીડ્સને સર્કિટ પોઈન્ટ સાથે જોડો જ્યાં વોલ્યુમtage needs to be measured. The multimeter will automatically detect AC or DC voltage.
  3. ભાગ વાંચોtage મૂલ્ય સ્ક્રીન પર પ્રદર્શિત થાય છે.
NJTY T3 Multimeter performing AC and DC voltagઇ પરીક્ષણો

Image: Two separate images showing the NJTY T3 Multimeter measuring AC voltage from a power strip and DC voltage from a 9V battery.

4. પ્રતિકાર માપન

  1. મહત્વપૂર્ણ: પ્રતિકાર માપતા પહેલા ખાતરી કરો કે સર્કિટ ડી-એનર્જાઇઝ્ડ છે.
  2. Connect the test leads across the component or circuit section where resistance is to be measured.
  3. The multimeter will display the resistance value in Ohms (Ω), Kilo-Ohms (KΩ), or Mega-Ohms (MΩ).
NJTY T3 Multimeter performing resistance and continuity tests

Image: Two separate images showing the NJTY T3 Multimeter measuring resistance of a resistor and performing a continuity test on a wire.

5. બિન-સંપર્ક વોલ્યુમtage (NCV) તપાસ

The NCV function allows for safe detection of live wires without direct contact.

  1. Press the NCV button (if available, or ensure NCV mode is active).
  2. Bring the NCV sensor at the top of the multimeter close to the wire or outlet.
  3. The multimeter will emit an audible beep and the display will indicate the presence of AC voltage, with increasing intensity as it gets closer to the source.
NJTY T3 Multimeter performing NCV detection near an electrical outlet

Image: The NJTY T3 Multimeter detecting non-contact voltage near an electrical wall outlet, with the screen showing "EF" and a signal strength indicator.

6. Live Wire Testing

આ ફંક્શન એસી સર્કિટમાં જીવંત વાયરને ઓળખવામાં મદદ કરે છે.

  1. Insert the red test probe into the socket or touch it to the wire you want to test.
  2. If the multimeter emits an alarm sound and the screen changes to indicate "LIVE", it signifies a live wire.
NJTY T3 Multimeter performing live wire testing on an electrical outlet

Image: The NJTY T3 Multimeter's red probe inserted into an electrical outlet for live wire testing, with the screen displaying "LIVE".

7. સાતત્ય પરીક્ષણ

  1. મહત્વપૂર્ણ: Ensure the circuit is de-energized before performing a continuity test.
  2. Connect the test leads across the component or wire to be tested.
  3. If continuity exists (resistance is low, typically below 50Ω), the multimeter will emit an audible beep.

8. ડેટા હોલ્ડ

Press the "HOLD" button to freeze the current reading on the display. Press it again to release the hold function.

૬.૨.૮. ફ્લેશલાઇટ અને બેકલાઇટ

The multimeter includes a built-in flashlight for illuminating the test area and a backlight for the display, enhancing visibility in low-light conditions. Refer to the device buttons for activation (typically a short press of the power button or a dedicated light button).

NJTY T3 Multimeter with flashlight illuminated

Image: The NJTY T3 Multimeter with its integrated flashlight active, illuminating a dark electrical panel.

જાળવણી

1. સફાઈ

Wipe the multimeter's case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any power source before cleaning.

2. બેટરી કેર

The built-in Lithium Ion battery should be charged regularly, especially if the device is not used for extended periods. The automatic shut-off feature helps prolong battery life. A low battery indicator will appear on the display when charging is required.

NJTY T3 Multimeter displaying a low battery warning

Image: The NJTY T3 Multimeter screen showing a low battery warning icon, indicating the need for recharging.

3. સંગ્રહ

Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. Disconnect test leads when storing.

મુશ્કેલીનિવારણ

સમસ્યાસંભવિત કારણઉકેલ
કોઈ ડિસ્પ્લે નહીં અથવા ઉપકરણ ચાલુ થશે નહીં.બેટરી ઓછી છે અથવા ઉપકરણ બંધ છે.Charge the battery using the Type-C cable. Press and hold the power button to turn on.
અચોક્કસ વાંચન.Poor test lead connection, incorrect measurement technique, or exceeding input limits.Ensure test leads are firmly connected. Review operating instructions for correct measurement procedures. Do not exceed specified input ranges.
Multimeter automatically shuts off.Automatic power-off feature activated due to inactivity.This is normal behavior to conserve battery. Press the power button to turn it back on.
NCV detection not working or inconsistent.Distance to voltage source too far, or interference.Bring the NCV sensor closer to the suspected live wire. Ensure no other strong electromagnetic fields are present.

વિશિષ્ટતાઓ

લક્ષણવિગત
ડિસ્પ્લે4000 Counts, 3.19-inch Color LCD
ડીસી વોલ્યુમtage રેન્જ0.8V - 600V (Accuracy: ±(0.8%+5))
એસી વોલ્યુમtage રેન્જ1V - 600V (Accuracy: ±(1.0%+5))
પ્રતિકાર શ્રેણી0 - 40MΩ (Accuracy: ±(1.0%+10))
Minimum Resolution (DCV/ACV)0.001 વી
Minimum Resolution (Resistance)
પાવર સ્ત્રોતરિચાર્જેબલ લિથિયમ આયન બેટરી (શામેલ)
ચાર્જિંગ પોર્ટટાઈપ-સી
આપોઆપ શટ-ઑફApproximately 15 minutes of inactivity
ફ્લેશલાઇટYes (1 minute auto shut-off)
બેકલાઇટહા
બઝરYes (for continuity, internal resistance less than 50Ω)
એનસીવી તપાસહા
સાચું RMSYes (45Hz-2KHz)
ઓછી બેટરી સૂચકહા
લાઈવ વાયર ઓળખહા
ઉત્પાદન પરિમાણો5.51 x 1.18 x 0.79 ઇંચ
વસ્તુનું વજન150 ગ્રામ (5.29 ઔંસ)
NJTY T3 Multimeter NCV detection and detailed specifications table

Image: The NJTY T3 Multimeter demonstrating NCV detection alongside a table detailing its technical specifications.

વોરંટી અને આધાર

વોરંટી માહિતી

For specific warranty terms and conditions, please refer to the warranty card included with your product or contact the seller directly. Warranty coverage typically addresses manufacturing defects under normal use.

ગ્રાહક આધાર

If you encounter any issues or have questions regarding the NJTY T3 Multimeter, please contact your retailer or the manufacturer's customer support channel. Refer to the "after-sales channel" information provided in your product packaging for contact details.

સંબંધિત દસ્તાવેજો - T3

પ્રિview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
User manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers features, safety, technical specifications, and operation for accurate electrical measurements.
પ્રિview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
Comprehensive user manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers specifications, safety, operation, and measurement functions for voltage, current, resistance, capacitance, inductance, frequency, and temperature.
પ્રિview NJTY પોઇન્ટર મલ્ટિમીટર વપરાશકર્તા માર્ગદર્શિકા: સુવિધાઓ, વિશિષ્ટતાઓ અને સૂચનાઓ
NJTY પોઈન્ટર મલ્ટિમીટર માટે વ્યાપક વપરાશકર્તા માર્ગદર્શિકા, તેના દેખાવ, વિશિષ્ટતાઓ, માપન કાર્યો (DC/AC વોલ્યુમ) ની વિગતો આપે છે.tage, વર્તમાન, પ્રતિકાર, કેપેસીટન્સ, વગેરે), અને મહત્વપૂર્ણ સલામતી રીમાઇન્ડર્સ.
પ્રિview NJTY S18D Digital Multimeter User Manual
User manual for the NJTY S18D Digital Multimeter, detailing safety instructions, panel indications, operational guidelines, and technical specifications for accurate electrical measurements. Features include IEC-61010 compliance, backlit LCD, True RMS, and auto-ranging.
પ્રિview NJTY 88 Series Analog Multimeter: User Manual & Technical Guide
Comprehensive user manual for the NJTY 88 series analog multimeters, covering features, specifications, safety precautions, and measurement instructions for DC/AC voltage and current, resistance, capacitance, frequency, and more.
પ્રિview NJTY T60 Series Insulation Resistance Tester Instruction Manual
Detailed instruction manual for NJTY T6005, T6010, and T6015 analog insulation resistance testers, covering features, operation, safety, technical specifications, and package contents.